Mobile LIDT
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F19%3A00542032" target="_blank" >RIV/68378271:_____/19:00542032 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.spiedigitallibrary.org/conference-proceedings-of-spie/11385/2542776/Mobile-LIDT/10.1117/12.2542776.short" target="_blank" >https://www.spiedigitallibrary.org/conference-proceedings-of-spie/11385/2542776/Mobile-LIDT/10.1117/12.2542776.short</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.2542776" target="_blank" >10.1117/12.2542776</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Mobile LIDT
Popis výsledku v původním jazyce
Laser Induced Damage Threshold (LIDT) is an important property of laser system components. It is obtained as a statistical value from controlled experiments and defines the maximum optical intensity, which does not cause damage to certain components. Correlation between maximum optical intensity, beam pulse length and focal spot size provides a unique characterization of a specimen. Some specimen requires conditions or environment unreachable in stationary setup, therefore a lighten, portable, version of testing setup may be used with proper source and surroundings. The advantage of the mobile LIDT station is access to different laser systems with variety of beam properties (repetition rate, pulse length, etc). In following paper were investigated accuracy of measurements done by the mobile LIDT station and copared to stationary, ISO compliant LIDT station measurements as reference.
Název v anglickém jazyce
Mobile LIDT
Popis výsledku anglicky
Laser Induced Damage Threshold (LIDT) is an important property of laser system components. It is obtained as a statistical value from controlled experiments and defines the maximum optical intensity, which does not cause damage to certain components. Correlation between maximum optical intensity, beam pulse length and focal spot size provides a unique characterization of a specimen. Some specimen requires conditions or environment unreachable in stationary setup, therefore a lighten, portable, version of testing setup may be used with proper source and surroundings. The advantage of the mobile LIDT station is access to different laser systems with variety of beam properties (repetition rate, pulse length, etc). In following paper were investigated accuracy of measurements done by the mobile LIDT station and copared to stationary, ISO compliant LIDT station measurements as reference.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Optics and Measurement International Conference
ISBN
978-1-5106-3548-7
ISSN
0277-786X
e-ISSN
—
Počet stran výsledku
6
Strana od-do
113850D
Název nakladatele
SPIE
Místo vydání
Bellingham
Místo konání akce
Liberec
Datum konání akce
8. 10. 2019
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000529302400012