Comparison of carbon-based electrodes for detection of cresols in voltammetry and HPLC with electrochemical detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F20%3A00537680" target="_blank" >RIV/68378271:_____/20:00537680 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11310/20:10419211
Výsledek na webu
<a href="https://doi.org/10.1002/elan.202060103" target="_blank" >https://doi.org/10.1002/elan.202060103</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.202060103" target="_blank" >10.1002/elan.202060103</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of carbon-based electrodes for detection of cresols in voltammetry and HPLC with electrochemical detection
Popis výsledku v původním jazyce
The electrochemical behavior of o‐cresol and p‐cresol was investigated using boron doped diamond (BDD) and sp2 carbon‐based electrodes. BDD electrodes with different boron doping levels were used to optimize conditions for detection of cresols using differential pulse and square‐wave voltammetry. Comparable detection limits from 2.74 μM to 0.79 μM were achieved, using in‐situ anodic pretreatment to prevent fouling of electrode surface. Lower detection limits for cresols and other phenolic pollutants, in the 10−7 M concentration range, were obtained using amperometric detection in HPLC. The proposed voltammetric and HPLC methods were utilized for determination of cresols in model river water samples.
Název v anglickém jazyce
Comparison of carbon-based electrodes for detection of cresols in voltammetry and HPLC with electrochemical detection
Popis výsledku anglicky
The electrochemical behavior of o‐cresol and p‐cresol was investigated using boron doped diamond (BDD) and sp2 carbon‐based electrodes. BDD electrodes with different boron doping levels were used to optimize conditions for detection of cresols using differential pulse and square‐wave voltammetry. Comparable detection limits from 2.74 μM to 0.79 μM were achieved, using in‐situ anodic pretreatment to prevent fouling of electrode surface. Lower detection limits for cresols and other phenolic pollutants, in the 10−7 M concentration range, were obtained using amperometric detection in HPLC. The proposed voltammetric and HPLC methods were utilized for determination of cresols in model river water samples.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10302 - Condensed matter physics (including formerly solid state physics, supercond.)
Návaznosti výsledku
Projekt
<a href="/cs/project/GA20-03187S" target="_blank" >GA20-03187S: Studium elektrochemických a adsorpčních dějů na nanostrukturovaných sp2 a sp3 uhlíkových površích ve vztahu k jejich fyzikálně chemickým vlastnostem</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
32
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
12
Strana od-do
2193-2204
Kód UT WoS článku
000548144400001
EID výsledku v databázi Scopus
2-s2.0-85087901033