Initial tests of large format sensors for the ATLAS ITk strip tracker
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F21%3A00541870" target="_blank" >RIV/68378271:_____/21:00541870 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1016/j.nima.2020.164677" target="_blank" >https://doi.org/10.1016/j.nima.2020.164677</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2020.164677" target="_blank" >10.1016/j.nima.2020.164677</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Initial tests of large format sensors for the ATLAS ITk strip tracker
Popis výsledku v původním jazyce
For the construction of the Inner Tracker (ITk) as part of the phase-II upgrade programme of the ATLAS detector or the High-Luminosity (HL) LHC, batches of Long Strip (LS) and Short Strip (SS) n+-in-p type micro-strip sensors have been produced by Hamamatsu Photonics and Infineon. The full size sensors measure approximately 98×98 mm2 and are designed and engineered for tolerance against the 9.7×1014 1 MeV neq/cm2 fluence expected at the HL-LHC, including a safety factor of 1.5. Each sensor has 2 or 4 columns of 1280 individual channels arranged at 75.5 μm horizontal pitch. To ensure the sensors comply with their specifications, a Quality Control (QC) procedure has been implemented, comprising measurements on every individual sensor as well as on a sample basis. Every sensor is subjected to an initial visual inspection, after which the full surface of the sensor is captured with very high resolution by an automated camera setup. Non-contact metrology is performed to obtain the sensor surface profile. Electrical measurements establishing the reverse bias leakage current and depletion voltage are then conducted automatically. Sample sensors from every batch are subjected to 40 h of leakage stability checks in controlled atmosphere, and tests on every channel measuring leakage current, coupling capacitance and bias resistance are done. The recorded results are uploaded to a production database following data quality checks. In this paper, QC test validation data and the compiled results for the first batches of production grade sensors are presented. The QC protocol was validated, and the first production sensors were confirmed to be within specification. The results are compared to those from the previous generation of prototype sensors.
Název v anglickém jazyce
Initial tests of large format sensors for the ATLAS ITk strip tracker
Popis výsledku anglicky
For the construction of the Inner Tracker (ITk) as part of the phase-II upgrade programme of the ATLAS detector or the High-Luminosity (HL) LHC, batches of Long Strip (LS) and Short Strip (SS) n+-in-p type micro-strip sensors have been produced by Hamamatsu Photonics and Infineon. The full size sensors measure approximately 98×98 mm2 and are designed and engineered for tolerance against the 9.7×1014 1 MeV neq/cm2 fluence expected at the HL-LHC, including a safety factor of 1.5. Each sensor has 2 or 4 columns of 1280 individual channels arranged at 75.5 μm horizontal pitch. To ensure the sensors comply with their specifications, a Quality Control (QC) procedure has been implemented, comprising measurements on every individual sensor as well as on a sample basis. Every sensor is subjected to an initial visual inspection, after which the full surface of the sensor is captured with very high resolution by an automated camera setup. Non-contact metrology is performed to obtain the sensor surface profile. Electrical measurements establishing the reverse bias leakage current and depletion voltage are then conducted automatically. Sample sensors from every batch are subjected to 40 h of leakage stability checks in controlled atmosphere, and tests on every channel measuring leakage current, coupling capacitance and bias resistance are done. The recorded results are uploaded to a production database following data quality checks. In this paper, QC test validation data and the compiled results for the first batches of production grade sensors are presented. The QC protocol was validated, and the first production sensors were confirmed to be within specification. The results are compared to those from the previous generation of prototype sensors.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
<a href="/cs/project/LTT17018" target="_blank" >LTT17018: Získávání nových poznatků o mikrosvětě v infrastruktuře CERN</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments & Methods in Physics Research Section A
ISSN
0168-9002
e-ISSN
1872-9576
Svazek periodika
986
Číslo periodika v rámci svazku
Jan
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
164677
Kód UT WoS článku
000594622600008
EID výsledku v databázi Scopus
2-s2.0-85092747845