The XY scanner - A versatile method of the absolute end-to-end calibration of fluorescence detectors
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F21%3A00552294" target="_blank" >RIV/68378271:_____/21:00552294 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15310/21:73610092
Výsledek na webu
<a href="https://pos.sissa.it/395/220/pdf" target="_blank" >https://pos.sissa.it/395/220/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.22323/1.395.0220" target="_blank" >10.22323/1.395.0220</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The XY scanner - A versatile method of the absolute end-to-end calibration of fluorescence detectors
Popis výsledku v původním jazyce
One of the crucial detector systems of the Pierre Auger Observatory is the fluorescence detector composed of 27 large-aperture wide-angle Schmidt telescopes. In the past, these telescopes were absolutely calibrated by illuminating the whole aperture with a uniform large-diameter light source. This absolute calibration was performed roughly once every three years, while a relative calibration was performed on a nightly basis. In this contribution, a new technique for an absolute end-to-end calibration of the fluorescence telescopes is presented. For this technique, a portable, calibrated light source mounted on a rail system is moved across the aperture of each telescope instead of illuminating the whole aperture at once. A dedicated setup using a combination of NIST traceable photodiodes to measure the mean intensity and a PMT for pulse-to-pulse stability tracking has been built for the absolute calibration of the light source.
Název v anglickém jazyce
The XY scanner - A versatile method of the absolute end-to-end calibration of fluorescence detectors
Popis výsledku anglicky
One of the crucial detector systems of the Pierre Auger Observatory is the fluorescence detector composed of 27 large-aperture wide-angle Schmidt telescopes. In the past, these telescopes were absolutely calibrated by illuminating the whole aperture with a uniform large-diameter light source. This absolute calibration was performed roughly once every three years, while a relative calibration was performed on a nightly basis. In this contribution, a new technique for an absolute end-to-end calibration of the fluorescence telescopes is presented. For this technique, a portable, calibrated light source mounted on a rail system is moved across the aperture of each telescope instead of illuminating the whole aperture at once. A dedicated setup using a combination of NIST traceable photodiodes to measure the mean intensity and a PMT for pulse-to-pulse stability tracking has been built for the absolute calibration of the light source.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
<a href="/cs/project/EF17_049%2F0008422" target="_blank" >EF17_049/0008422: Partnerská síť v oblasti výzkumu a vývoje zobrazovací a osvětlovací techniky a optoelektroniky pro optický a automobilový průmysl</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of Science
ISBN
—
ISSN
1824-8039
e-ISSN
—
Počet stran výsledku
12
Strana od-do
220
Název nakladatele
Sissa Medilab srl
Místo vydání
Trieste
Místo konání akce
Berlin
Datum konání akce
12. 7. 2021
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—