Gas sensing properties of a nanocrystalline diamond with a hydrogen-terminated surface (H-terminated NCD) and a molybdenum disulphide (MoS2) are investigated as conductivity sensors with built-in interdigital metal electrode structures. The H-terminated NCD was prepared by plasma-enhanced chemical vapour deposition (PECVD), and the MoS2 by a carbide-free one-zone sulfurization method. The sensor's responses were measured for oxidizing (NO2) and reducing (NH3) gases by the same equipment and setup. The parameters of the tested sensors are compared and critically evaluated. Advantageously, the MoS2/H-terminated NCD heterostructure enhances the gas sensing response at room temperature compared to the H-terminated NCD and MoS2 layers.
Název v anglickém jazyce
Development and measurement of gas sensors for room temperature applications
Popis výsledku anglicky
Gas sensing properties of a nanocrystalline diamond with a hydrogen-terminated surface (H-terminated NCD) and a molybdenum disulphide (MoS2) are investigated as conductivity sensors with built-in interdigital metal electrode structures. The H-terminated NCD was prepared by plasma-enhanced chemical vapour deposition (PECVD), and the MoS2 by a carbide-free one-zone sulfurization method. The sensor's responses were measured for oxidizing (NO2) and reducing (NH3) gases by the same equipment and setup. The parameters of the tested sensors are compared and critically evaluated. Advantageously, the MoS2/H-terminated NCD heterostructure enhances the gas sensing response at room temperature compared to the H-terminated NCD and MoS2 layers.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the Student International Conference on Electrical Engineering /26./
ISBN
978-80-01-06992-9
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
70-72
Název nakladatele
Czech Technical University in Prague
Místo vydání
Prague
Místo konání akce
Prague
Datum konání akce
12. 5. 2022
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—