Properties of focusing polycapillary utilized in 57Fe Mössbauer spectroscopy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F22%3A00561959" target="_blank" >RIV/68378271:_____/22:00561959 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15310/22:73612930
Výsledek na webu
<a href="https://doi.org/10.1016/j.measurement.2022.110842" target="_blank" >https://doi.org/10.1016/j.measurement.2022.110842</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.measurement.2022.110842" target="_blank" >10.1016/j.measurement.2022.110842</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Properties of focusing polycapillary utilized in 57Fe Mössbauer spectroscopy
Popis výsledku v původním jazyce
A focusing polycapillary was incorporated in the Mossbauer spectrometer to achieve Mossbauer spectrum from the point with the diameter of 150 mu m. Since such an apparatus is rather unique and so far it has not been described, a detailed views into the problematics of using the focusing polycapillary with Co-57 source, and into the problematics of the scanning transmission Mossbauer microscope alignment procedure are presented. This article presents the properties of the focusing polycapillary and its performance for Fe-57 14.4 keV Mossbauer radiation using Co-57 radioactive source. The performance of the polycapillary is demonstrated with the measurement of the stainless steel. The obtained spectrum exhibited a similar signal to noise ratio as the Mossbauer spectrum acquired by using a pinhole with the diameter of 200 mu m. The usage of the polycapillary optics could be a promising way in Mossbauer spectroscopy, e.g. for measurements of tiny samples in an anvil cell.n
Název v anglickém jazyce
Properties of focusing polycapillary utilized in 57Fe Mössbauer spectroscopy
Popis výsledku anglicky
A focusing polycapillary was incorporated in the Mossbauer spectrometer to achieve Mossbauer spectrum from the point with the diameter of 150 mu m. Since such an apparatus is rather unique and so far it has not been described, a detailed views into the problematics of using the focusing polycapillary with Co-57 source, and into the problematics of the scanning transmission Mossbauer microscope alignment procedure are presented. This article presents the properties of the focusing polycapillary and its performance for Fe-57 14.4 keV Mossbauer radiation using Co-57 radioactive source. The performance of the polycapillary is demonstrated with the measurement of the stainless steel. The obtained spectrum exhibited a similar signal to noise ratio as the Mossbauer spectrum acquired by using a pinhole with the diameter of 200 mu m. The usage of the polycapillary optics could be a promising way in Mossbauer spectroscopy, e.g. for measurements of tiny samples in an anvil cell.n
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Measurement
ISSN
0263-2241
e-ISSN
1873-412X
Svazek periodika
192
Číslo periodika v rámci svazku
Mar
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
110842
Kód UT WoS článku
000781371600005
EID výsledku v databázi Scopus
2-s2.0-85125438540