The upgrade of the Pierre Auger Observatory with the Scintillator Surface Detector.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F22%3A00564666" target="_blank" >RIV/68378271:_____/22:00564666 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15120/22:73616895 RIV/61989592:15310/22:73616895
Výsledek na webu
<a href="https://pos.sissa.it/395/251/pdf" target="_blank" >https://pos.sissa.it/395/251/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.22323/1.395.0251" target="_blank" >10.22323/1.395.0251</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The upgrade of the Pierre Auger Observatory with the Scintillator Surface Detector.
Popis výsledku v původním jazyce
Since its full commissioning in 2008, the Pierre Auger Observatory has consistently demonstrated its scientific productivity. A major upgrade of the Surface Detector array (SD) improves the capabilities of measuring the different components of extensive air showers. One of the elements of the upgrade consists of new Scintillator Surface Detectors (SSD) placed on top of the Water-Cherenkov stations of the SD. At the Observatory, the integration of the SSD components and their deployment in the array is well advanced. In this paper, the main challenges and characteristics of the construction and installation will be reviewed. Started in 2016, an Engineering Array of twelve upgraded stations has been taking data in the field. In March 2019, a preproduction array of 77 SSDs started data acquisition with an adapted version of non-upgraded electronics. It is collecting events and proving the goodness of SSD design.
Název v anglickém jazyce
The upgrade of the Pierre Auger Observatory with the Scintillator Surface Detector.
Popis výsledku anglicky
Since its full commissioning in 2008, the Pierre Auger Observatory has consistently demonstrated its scientific productivity. A major upgrade of the Surface Detector array (SD) improves the capabilities of measuring the different components of extensive air showers. One of the elements of the upgrade consists of new Scintillator Surface Detectors (SSD) placed on top of the Water-Cherenkov stations of the SD. At the Observatory, the integration of the SSD components and their deployment in the array is well advanced. In this paper, the main challenges and characteristics of the construction and installation will be reviewed. Started in 2016, an Engineering Array of twelve upgraded stations has been taking data in the field. In March 2019, a preproduction array of 77 SSDs started data acquisition with an adapted version of non-upgraded electronics. It is collecting events and proving the goodness of SSD design.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of Science
ISBN
—
ISSN
1824-8039
e-ISSN
—
Počet stran výsledku
12
Strana od-do
251
Název nakladatele
Sissa Medilab srl
Místo vydání
Trieste
Místo konání akce
Berlin
Datum konání akce
12. 7. 2021
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—