Development of bases and qualification tests of Photomultiplier Tubes for the AugerPrime scintillation detectors
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F22%3A00566484" target="_blank" >RIV/68378271:_____/22:00566484 - isvavai.cz</a>
Výsledek na webu
<a href="https://pos.sissa.it/395/265" target="_blank" >https://pos.sissa.it/395/265</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.22323/1.395.0265" target="_blank" >10.22323/1.395.0265</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development of bases and qualification tests of Photomultiplier Tubes for the AugerPrime scintillation detectors
Popis výsledku v původním jazyce
We describe two test benches that were designed and constructed to perform a set of acceptance tests for about 1200 Photomultiplier Tube (PMT) units to be installed in the surface scintillation detectors of AugerPrime. Besides possessing robustness, long-term reliability, and low power consumption, each PMT-unit requires a dynamic range wide enough to cover signals ranging from a single to more than 20,000 minimum ionizing particles with not more than 5 % deviation from linear response. This posed a particular challenge which was met by combining a specially selected 1.5” PMT type with a custom made Cockcroft Walton type base.n
Název v anglickém jazyce
Development of bases and qualification tests of Photomultiplier Tubes for the AugerPrime scintillation detectors
Popis výsledku anglicky
We describe two test benches that were designed and constructed to perform a set of acceptance tests for about 1200 Photomultiplier Tube (PMT) units to be installed in the surface scintillation detectors of AugerPrime. Besides possessing robustness, long-term reliability, and low power consumption, each PMT-unit requires a dynamic range wide enough to cover signals ranging from a single to more than 20,000 minimum ionizing particles with not more than 5 % deviation from linear response. This posed a particular challenge which was met by combining a specially selected 1.5” PMT type with a custom made Cockcroft Walton type base.n
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
—
Návaznosti
—
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of Science
ISBN
—
ISSN
1824-8039
e-ISSN
—
Počet stran výsledku
8
Strana od-do
265
Název nakladatele
Sissa Medilab srl
Místo vydání
Trieste
Místo konání akce
Berlin
Datum konání akce
12. 7. 2021
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—