Development of a calibration light source based on a unique modification of an integrating sphere
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F25%3A00619454" target="_blank" >RIV/68378271:_____/25:00619454 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15310/25:73631407
Výsledek na webu
<a href="https://doi.org/10.1016/j.optlastec.2025.112766" target="_blank" >https://doi.org/10.1016/j.optlastec.2025.112766</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.optlastec.2025.112766" target="_blank" >10.1016/j.optlastec.2025.112766</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development of a calibration light source based on a unique modification of an integrating sphere
Popis výsledku v původním jazyce
The precise determination of the energy scale is of utmost importance for many experiments in astroparticle physics. Thus, the detectors of such experiments have to be properly calibrated. This paper focuses on the complex but cost-effective modification of a general purpose integrating sphere to develop a calibration light source. The key parameter of the calibration light source is the radiance uniformity, which is optimized using a validated optical simulation model. Based on the results of the optical simulation, a prototype of a modified integrating sphere is assembled in our laboratory. Its radiance uniformity is subsequently measured and crosschecked with the optical simulation, proving the concept of the optimization. The achieved improvement in the radiance uniformity is discussed and demonstrated by a comparison of the results of the developed prototype with the results of the general purpose integrating sphere.
Název v anglickém jazyce
Development of a calibration light source based on a unique modification of an integrating sphere
Popis výsledku anglicky
The precise determination of the energy scale is of utmost importance for many experiments in astroparticle physics. Thus, the detectors of such experiments have to be properly calibrated. This paper focuses on the complex but cost-effective modification of a general purpose integrating sphere to develop a calibration light source. The key parameter of the calibration light source is the radiance uniformity, which is optimized using a validated optical simulation model. Based on the results of the optical simulation, a prototype of a modified integrating sphere is assembled in our laboratory. Its radiance uniformity is subsequently measured and crosschecked with the optical simulation, proving the concept of the optimization. The achieved improvement in the radiance uniformity is discussed and demonstrated by a comparison of the results of the developed prototype with the results of the general purpose integrating sphere.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
<a href="/cs/project/EF17_049%2F0008422" target="_blank" >EF17_049/0008422: Partnerská síť v oblasti výzkumu a vývoje zobrazovací a osvětlovací techniky a optoelektroniky pro optický a automobilový průmysl</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Optics and Laser Technology
ISSN
0030-3992
e-ISSN
1879-2545
Svazek periodika
187
Číslo periodika v rámci svazku
Sept
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
14
Strana od-do
112766
Kód UT WoS článku
001467602500001
EID výsledku v databázi Scopus
2-s2.0-105000380804