Influence of Wind Conditions on the FSO link attenuation at Milešovka Hill
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378289%3A_____%2F12%3A00390804" target="_blank" >RIV/68378289:_____/12:00390804 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of Wind Conditions on the FSO link attenuation at Milešovka Hill
Popis výsledku v původním jazyce
The influence of wind at FSO link attenuation at Milešovka hill has been studied for the last three years (2009 ? 2011). New database of all measured data (meteorological elements and attenuation data) in Matlab software has been made for simple calculations and operational processes with this data. Correlations between wind characteristics and attenuation were calculated and presented in this study. Results show the influence of almost all wind parameters at FSO link attenuation, but this influence isvery weak except of sonic temperature. The directional graphs show that wind direction at the tower position is more influenced by the FSO link attenuation than wind direction at the lamp (lower) position.
Název v anglickém jazyce
Influence of Wind Conditions on the FSO link attenuation at Milešovka Hill
Popis výsledku anglicky
The influence of wind at FSO link attenuation at Milešovka hill has been studied for the last three years (2009 ? 2011). New database of all measured data (meteorological elements and attenuation data) in Matlab software has been made for simple calculations and operational processes with this data. Correlations between wind characteristics and attenuation were calculated and presented in this study. Results show the influence of almost all wind parameters at FSO link attenuation, but this influence isvery weak except of sonic temperature. The directional graphs show that wind direction at the tower position is more influenced by the FSO link attenuation than wind direction at the lamp (lower) position.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
DG - Vědy o atmosféře, meteorologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/OC09027" target="_blank" >OC09027: Vlivu oblaků,mlh a deště na optické i radiové bezdrátové spoje</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů