Evaluation of strain field in microstructures using micro-CT and digital volume correlation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378297%3A_____%2F11%3A00354592" target="_blank" >RIV/68378297:_____/11:00354592 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21670/11:00178253
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of strain field in microstructures using micro-CT and digital volume correlation
Popis výsledku v původním jazyce
X-ray digital micro-tomography was employed for precise strain measurement which is essential for evaluation of the experiments with small samples of trabecular bone. X-ray Digital Volumetric Correlation (DVC) method was used to identify the three-dimensional strain field in loaded complex microstructure. DVC relies on tracking selected sample points within the threedimensional image data throughout the sequence of captured projections. In this study an improved DVC method is applied for evaluation of the strain field in trabecular bone sample subjected to compressive loading. The deformed sample was tomographically scanned using micro-focus X-ray tube and the single-photon counting silicon pixel detector Medipix2.
Název v anglickém jazyce
Evaluation of strain field in microstructures using micro-CT and digital volume correlation
Popis výsledku anglicky
X-ray digital micro-tomography was employed for precise strain measurement which is essential for evaluation of the experiments with small samples of trabecular bone. X-ray Digital Volumetric Correlation (DVC) method was used to identify the three-dimensional strain field in loaded complex microstructure. DVC relies on tracking selected sample points within the threedimensional image data throughout the sequence of captured projections. In this study an improved DVC method is applied for evaluation of the strain field in trabecular bone sample subjected to compressive loading. The deformed sample was tomographically scanned using micro-focus X-ray tube and the single-photon counting silicon pixel detector Medipix2.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JJ - Ostatní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP105%2F10%2F2305" target="_blank" >GAP105/10/2305: Morfometrické a mechanické vlastnosti trabekulární kosti zjištěné pomocí metod mikromechaniky a numerického modelování</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Svazek periodika
6
Číslo periodika v rámci svazku
—
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
—