Assessment of micromechanical properties of trabecular bone using quantitative backscattered electron microscopy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378297%3A_____%2F12%3A00377538" target="_blank" >RIV/68378297:_____/12:00377538 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.itam.cas.cz/bilateral2012/proceedings.php" target="_blank" >http://www.itam.cas.cz/bilateral2012/proceedings.php</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assessment of micromechanical properties of trabecular bone using quantitative backscattered electron microscopy
Popis výsledku v původním jazyce
The biomechanical behaviour of trabecular bone depends not only on its microarchitecture but also on mineral density distribution. Bone mineral density distribution is coupled with mechanical properties of the tissue. In this preliminary study intratrabecular composition of individual trabeculae was investigated. The quantitative backscattered electron microscopy (qBSE) a method based on detection of electrons backscattered from surface layer of the specimen was employed to obtain high resolution imagesof the transverse sections of a trabecula. From acquired data the element map was created, organic (collagen fibres) to anorganic (hydroxyapatite) material ratio computed and collagen fibres orientation assessed. To conclude qBSE allows to obtain detailinformation about intratrabecular composition and material properties at the level of individual trabeculae.
Název v anglickém jazyce
Assessment of micromechanical properties of trabecular bone using quantitative backscattered electron microscopy
Popis výsledku anglicky
The biomechanical behaviour of trabecular bone depends not only on its microarchitecture but also on mineral density distribution. Bone mineral density distribution is coupled with mechanical properties of the tissue. In this preliminary study intratrabecular composition of individual trabeculae was investigated. The quantitative backscattered electron microscopy (qBSE) a method based on detection of electrons backscattered from surface layer of the specimen was employed to obtain high resolution imagesof the transverse sections of a trabecula. From acquired data the element map was created, organic (collagen fibres) to anorganic (hydroxyapatite) material ratio computed and collagen fibres orientation assessed. To conclude qBSE allows to obtain detailinformation about intratrabecular composition and material properties at the level of individual trabeculae.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JJ - Ostatní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP105%2F10%2F2305" target="_blank" >GAP105/10/2305: Morfometrické a mechanické vlastnosti trabekulární kosti zjištěné pomocí metod mikromechaniky a numerického modelování</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Experimental Methods and Numerical Simulation in Engineering Sciences
ISBN
978-80-01-05062-0
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
119-122
Název nakladatele
Czech Technical University, Faculty of Transportation Sciences
Místo vydání
Praha
Místo konání akce
Telč
Datum konání akce
5. 6. 2012
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—