Instrumentation for Micromechanics Research in Trabecular Bone
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378297%3A_____%2F13%3A00389470" target="_blank" >RIV/68378297:_____/13:00389470 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.2316/P.2013.791-064" target="_blank" >http://dx.doi.org/10.2316/P.2013.791-064</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2316/P.2013.791-064" target="_blank" >10.2316/P.2013.791-064</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Instrumentation for Micromechanics Research in Trabecular Bone
Popis výsledku v původním jazyce
This article deals with description of instrumentation required for micromechanical testing of isolated trabeculae, the basic structural elements of cancellous bone. Process of tensile and bending tests is described in terms of development of the testingdevices, challenges connected with the micro-scale testing and precision of the measurements. The paper covers the whole testing procedure from tissue harvesting, sample preparation, experimental procedure and data evaluation. Inverse finite element identification of elasto-plastic material model with damage based on three-point bending for simulation of deformation behaviour of trabecular bone is shortly discussed as well.
Název v anglickém jazyce
Instrumentation for Micromechanics Research in Trabecular Bone
Popis výsledku anglicky
This article deals with description of instrumentation required for micromechanical testing of isolated trabeculae, the basic structural elements of cancellous bone. Process of tensile and bending tests is described in terms of development of the testingdevices, challenges connected with the micro-scale testing and precision of the measurements. The paper covers the whole testing procedure from tissue harvesting, sample preparation, experimental procedure and data evaluation. Inverse finite element identification of elasto-plastic material model with damage based on three-point bending for simulation of deformation behaviour of trabecular bone is shortly discussed as well.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FI - Traumatologie a ortopedie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP105%2F10%2F2305" target="_blank" >GAP105/10/2305: Morfometrické a mechanické vlastnosti trabekulární kosti zjištěné pomocí metod mikromechaniky a numerického modelování</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 10th IASTED international conference on Biomedical Engineering
ISBN
978-0-88986-942-4
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
120-124
Název nakladatele
ACTA Press
Místo vydání
Calgary
Místo konání akce
Innsbruck
Datum konání akce
13. 2. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—