Compressive behaviour of trabecular tissue: finite element modelling and comparison using digital volume correlation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378297%3A_____%2F13%3A00396013" target="_blank" >RIV/68378297:_____/13:00396013 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Compressive behaviour of trabecular tissue: finite element modelling and comparison using digital volume correlation
Popis výsledku v původním jazyce
In this paper the deformation behaviour of the complex structure of a trabecular bone is investigated using the finite element (FE) simulation of a compression test. To obtain a geometrically accurate FE model of the trabecular microstructure and suitable experimental data for model validation time?lapsemicro-CT scanning of the compression test was undertaken. The sample was placed in a loading device and subjected to incremental compressive loading (up to 6 % deformation with 1 % strain increments) andobserved using a fine?focus X-ray microradiographic imaging. Tomography of the sample was performed at each load step and the radiograms were reconstructed using the cone beam reconstruction technique to obtain spatial image data of the deformation process. Reconstructed image data of each load state enables the FE model to be valiated and the constitutive relations used for description of the deformation behaviour to be tested.
Název v anglickém jazyce
Compressive behaviour of trabecular tissue: finite element modelling and comparison using digital volume correlation
Popis výsledku anglicky
In this paper the deformation behaviour of the complex structure of a trabecular bone is investigated using the finite element (FE) simulation of a compression test. To obtain a geometrically accurate FE model of the trabecular microstructure and suitable experimental data for model validation time?lapsemicro-CT scanning of the compression test was undertaken. The sample was placed in a loading device and subjected to incremental compressive loading (up to 6 % deformation with 1 % strain increments) andobserved using a fine?focus X-ray microradiographic imaging. Tomography of the sample was performed at each load step and the radiograms were reconstructed using the cone beam reconstruction technique to obtain spatial image data of the deformation process. Reconstructed image data of each load state enables the FE model to be valiated and the constitutive relations used for description of the deformation behaviour to be tested.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JJ - Ostatní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP105%2F10%2F2305" target="_blank" >GAP105/10/2305: Morfometrické a mechanické vlastnosti trabekulární kosti zjištěné pomocí metod mikromechaniky a numerického modelování</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the Fourteenth International Conference on Civil, Structural and Environmental Engineering Computing
ISBN
978-1-905088-57-7
ISSN
1759-3433
e-ISSN
—
Počet stran výsledku
15
Strana od-do
—
Název nakladatele
Civil-Comp Press
Místo vydání
Kippen
Místo konání akce
Cagliari
Datum konání akce
3. 9. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—