Utilization of dual-source X-ray tomography for reduction of scanning time of wooden samples
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378297%3A_____%2F15%3A00444421" target="_blank" >RIV/68378297:_____/15:00444421 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21670/15:00232405
Výsledek na webu
<a href="http://iopscience.iop.org/article/10.1088/1748-0221/10/05/C05008" target="_blank" >http://iopscience.iop.org/article/10.1088/1748-0221/10/05/C05008</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/10/05/C05008" target="_blank" >10.1088/1748-0221/10/05/C05008</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Utilization of dual-source X-ray tomography for reduction of scanning time of wooden samples
Popis výsledku v původním jazyce
We present a novel dual-source/dual energy (DSCT/DECT) micro-tomography system including results of high-resolution DSCT reconstruction. The DSCT micro-tomography setup was designed as a multi-purpose X-ray imaging device equipped with two pairs of X-ray tubes and detectors in orthogonal arrangement with independent control of beam parameters. Both pairs (tube-detector) are mounted on a computer numerical control positioning system and can be independently set up to different geometries (e.g. with different magnification of each pair). In this work the simultaneous scanning of the object by two tube-detector pairs was used for approximately half reduction of tomography scanning time. The developed imaging procedure was applied for scanning of a wooden sample locally damaged during a semi-destructive test for assessment of wood quality. Prior to the tomography measurements the setup geometry was precisely adjusted in terms of magnification, horizontal and vertical tube-specimen-detector alignment of both pairs. DSCT measurements were carried out in sequence (2 x90 ° for each tube) with identical 100μm image resolution. It was proven that the presented experimental setup combined with appropriate control technique significantly reduces tomography scanning time of materials with complex micro-structure.
Název v anglickém jazyce
Utilization of dual-source X-ray tomography for reduction of scanning time of wooden samples
Popis výsledku anglicky
We present a novel dual-source/dual energy (DSCT/DECT) micro-tomography system including results of high-resolution DSCT reconstruction. The DSCT micro-tomography setup was designed as a multi-purpose X-ray imaging device equipped with two pairs of X-ray tubes and detectors in orthogonal arrangement with independent control of beam parameters. Both pairs (tube-detector) are mounted on a computer numerical control positioning system and can be independently set up to different geometries (e.g. with different magnification of each pair). In this work the simultaneous scanning of the object by two tube-detector pairs was used for approximately half reduction of tomography scanning time. The developed imaging procedure was applied for scanning of a wooden sample locally damaged during a semi-destructive test for assessment of wood quality. Prior to the tomography measurements the setup geometry was precisely adjusted in terms of magnification, horizontal and vertical tube-specimen-detector alignment of both pairs. DSCT measurements were carried out in sequence (2 x90 ° for each tube) with identical 100μm image resolution. It was proven that the presented experimental setup combined with appropriate control technique significantly reduces tomography scanning time of materials with complex micro-structure.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
AL - Umění, architektura, kulturní dědictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/DF11P01OVV001" target="_blank" >DF11P01OVV001: Diagnostika poškozování a životnosti objektů kulturního dědictví</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
11
Strana od-do
"C05008"
Kód UT WoS článku
000357993300008
EID výsledku v databázi Scopus
2-s2.0-84929190994