Correction of the X-ray tube spot movement as a tool for improvement of the micro-tomography quality
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378297%3A_____%2F16%3A00458310" target="_blank" >RIV/68378297:_____/16:00458310 - isvavai.cz</a>
Výsledek na webu
<a href="http://iopscience.iop.org/article/10.1088/1748-0221/11/01/C01029" target="_blank" >http://iopscience.iop.org/article/10.1088/1748-0221/11/01/C01029</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/11/01/C01029" target="_blank" >10.1088/1748-0221/11/01/C01029</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Correction of the X-ray tube spot movement as a tool for improvement of the micro-tomography quality
Popis výsledku v původním jazyce
Nowadays X-ray tubes in conjunction with digital pixelated imagers are standardly utilized for high resolution radiography with several micrometre or even sub-micrometre resolution. Achievement of the same resolution in X-ray computed tomography is a more demanding task due to the time-dependent tube electron beam drift as well as thermal deformations of the tube. In our work, the beam drift caused by the long-term stabilization of the tube electron optics was measured by observation of radiographs of 75 μm big tin ball rigidly mounted onto the tube head. The tube spot movement comprising both the beam drift and the movement caused by thermal deformations of the tube and its fixture was evaluated measuring the virtual movement of the inspected object. For this purpose, radiographs were recorded periodically at the same object position. Both the beam drift as well as spot movement were evaluated with subpixel resolution using digital image correlation tools. It was proven that the quality of a tomographic reconstruction can be significantly improved by the correction of the spot movement.
Název v anglickém jazyce
Correction of the X-ray tube spot movement as a tool for improvement of the micro-tomography quality
Popis výsledku anglicky
Nowadays X-ray tubes in conjunction with digital pixelated imagers are standardly utilized for high resolution radiography with several micrometre or even sub-micrometre resolution. Achievement of the same resolution in X-ray computed tomography is a more demanding task due to the time-dependent tube electron beam drift as well as thermal deformations of the tube. In our work, the beam drift caused by the long-term stabilization of the tube electron optics was measured by observation of radiographs of 75 μm big tin ball rigidly mounted onto the tube head. The tube spot movement comprising both the beam drift and the movement caused by thermal deformations of the tube and its fixture was evaluated measuring the virtual movement of the inspected object. For this purpose, radiographs were recorded periodically at the same object position. Both the beam drift as well as spot movement were evaluated with subpixel resolution using digital image correlation tools. It was proven that the quality of a tomographic reconstruction can be significantly improved by the correction of the spot movement.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
AL - Umění, architektura, kulturní dědictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1219" target="_blank" >LO1219: Udržitelný pokročilý rozvoj CET</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Svazek periodika
11
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
"C01029"
Kód UT WoS článku
000371469800029
EID výsledku v databázi Scopus
2-s2.0-84957042711