Localization of simulated damage on a steel beam from random vibrations
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378297%3A_____%2F18%3A00482249" target="_blank" >RIV/68378297:_____/18:00482249 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21610/18:00320066
Výsledek na webu
<a href="https://doi.org/10.3311/PPci.10625" target="_blank" >https://doi.org/10.3311/PPci.10625</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3311/PPci.10625" target="_blank" >10.3311/PPci.10625</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Localization of simulated damage on a steel beam from random vibrations
Popis výsledku v původním jazyce
The performance of a few localization schemes using measured mode shapes was tested in an experimental case study with respect to the Ultimate Limit State (ULS). The first question to be posed was: Is it possible to indicate and locate damage under laboratory conditions before the ULS is reached? Relatively simple localization criteria were chosen, which do not require extensive FE analysis. A new combination of them, designated here as Combined Localization Criterion (CLI), was proposed that performed well in the presented case. A simple supported beam with the damage progressing in three consecutive stages was used for the experiments. Mode shapes in the range of up to 100 Hz were extracted from the response of the structure to the air stream.
Název v anglickém jazyce
Localization of simulated damage on a steel beam from random vibrations
Popis výsledku anglicky
The performance of a few localization schemes using measured mode shapes was tested in an experimental case study with respect to the Ultimate Limit State (ULS). The first question to be posed was: Is it possible to indicate and locate damage under laboratory conditions before the ULS is reached? Relatively simple localization criteria were chosen, which do not require extensive FE analysis. A new combination of them, designated here as Combined Localization Criterion (CLI), was proposed that performed well in the presented case. A simple supported beam with the damage progressing in three consecutive stages was used for the experiments. Mode shapes in the range of up to 100 Hz were extracted from the response of the structure to the air stream.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20102 - Construction engineering, Municipal and structural engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GC17-26353J" target="_blank" >GC17-26353J: Teoretické prediktivní modely interakce proměnného a pohyblivého zatížení využitelné v monitoringu mostních konstrukcí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Periodica Polytechnica. Civil Engineering
ISSN
0553-6626
e-ISSN
—
Svazek periodika
62
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
HU - Maďarsko
Počet stran výsledku
5
Strana od-do
112-116
Kód UT WoS článku
000415049300012
EID výsledku v databázi Scopus
2-s2.0-85032701406