Recommendation of RILEM TC 243-SGM: functional requirements for surface repair mortars for historic buildings
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378297%3A_____%2F19%3A00496522" target="_blank" >RIV/68378297:_____/19:00496522 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1617/s11527-018-1284-y" target="_blank" >https://doi.org/10.1617/s11527-018-1284-y</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1617/s11527-018-1284-y" target="_blank" >10.1617/s11527-018-1284-y</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Recommendation of RILEM TC 243-SGM: functional requirements for surface repair mortars for historic buildings
Popis výsledku v původním jazyce
Surface repair mortars are used for the compensation, or repair, of lost portions of surface materials in historic masonry buildings. It is recommended that their design and application should be performed in a wider context of conservation values related decision making, to prioritise preservation of original fabric, authenticity of approach and maintenance of integrity, and not just on technical principles alone. However, a technical context for their design does exist, that requires understanding of the properties of the substrate that they will be applied onto, and adherence to minimum aesthetic (colour and texture) requirements. The principles of physical, mechanical and chemical compatibility of repair apply and the attributes of the repair mortar should be carefully matched to the substrate alongside a sacrificial behaviour (not more durable than the material being replaced). Guidance is given on the design, application and the functional requirements that must be met when using surface repair mortars.
Název v anglickém jazyce
Recommendation of RILEM TC 243-SGM: functional requirements for surface repair mortars for historic buildings
Popis výsledku anglicky
Surface repair mortars are used for the compensation, or repair, of lost portions of surface materials in historic masonry buildings. It is recommended that their design and application should be performed in a wider context of conservation values related decision making, to prioritise preservation of original fabric, authenticity of approach and maintenance of integrity, and not just on technical principles alone. However, a technical context for their design does exist, that requires understanding of the properties of the substrate that they will be applied onto, and adherence to minimum aesthetic (colour and texture) requirements. The principles of physical, mechanical and chemical compatibility of repair apply and the attributes of the repair mortar should be carefully matched to the substrate alongside a sacrificial behaviour (not more durable than the material being replaced). Guidance is given on the design, application and the functional requirements that must be met when using surface repair mortars.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Materials and Structures
ISSN
1359-5997
e-ISSN
—
Svazek periodika
52
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
18
Strana od-do
28
Kód UT WoS článku
000458667500001
EID výsledku v databázi Scopus
2-s2.0-85061483110