Popis výsledku v původním jazyce
This work presents X-ray computed tomography of a harmonically oscillating elastic beam. The tomographic imaging is achieved by obtaining projections of the object in its maximum amplitude to capture the eigenmode of the beam using a triggered computed tomography method synchronized with the oscillation of the beam. Related instrumentation, experimental methodology and data post-processing are presented. Results are demonstrated on the reconstructed 3D images of the polymeric oscillating beam in its deformed shape corresponding with the harmonic excitation using the first eigenfrequency. A comparison with conventional non-synchronized tomography of the oscillating beam in its first eigenfrequency is presented to highlight fundamental advantages on such tomographical imaging.
Název v anglickém jazyce
X-ray computed tomography of the oscillating beam
Popis výsledku anglicky
This work presents X-ray computed tomography of a harmonically oscillating elastic beam. The tomographic imaging is achieved by obtaining projections of the object in its maximum amplitude to capture the eigenmode of the beam using a triggered computed tomography method synchronized with the oscillation of the beam. Related instrumentation, experimental methodology and data post-processing are presented. Results are demonstrated on the reconstructed 3D images of the polymeric oscillating beam in its deformed shape corresponding with the harmonic excitation using the first eigenfrequency. A comparison with conventional non-synchronized tomography of the oscillating beam in its first eigenfrequency is presented to highlight fundamental advantages on such tomographical imaging.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA22-13811S" target="_blank" >GA22-13811S: Inovativní defektoskopická metoda založená na tomografické analýze vlastních tvarů kmitání ve 3D</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
62nd International Scientific Conference on Experimental Stress Analysis (EAN 2024)
ISBN
979-8-3313-1105-6
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1
Název nakladatele
Czech Society for Mechanics
Místo vydání
Praha
Místo konání akce
Boží Dar
Datum konání akce
4. 6. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—