Thermal conductivity, specific heat and linear thermal expansion coefficient are measured in the temperature range from 100 C to 800 C and in the moisture range from dry material to saturation water content. Linear hygric expansion coefficient is measured in the whole moisture range from dry material to full water saturation. Moisture diffusivity is measured as a function of temperature up to 80 C, and the effects of high-temperature exposure up to 800 C and freeze/thaw cycles on its value are studied.In order to analyze the observed changes in moisture diffusivity and thermal parameters, thermal analysis and visual analysis are performed. As the main reason for these changes, the crack formation is identified. Particularly, the magnitude of variations of moisture diffusivity is found to be affected by the quality of aggregates rather than by the quality of cement
Název v anglickém jazyce
Hygric and Thermal Properties of HPC for Concrete Containments of Nuclear Power Plants
Popis výsledku anglicky
Thermal conductivity, specific heat and linear thermal expansion coefficient are measured in the temperature range from 100 C to 800 C and in the moisture range from dry material to saturation water content. Linear hygric expansion coefficient is measured in the whole moisture range from dry material to full water saturation. Moisture diffusivity is measured as a function of temperature up to 80 C, and the effects of high-temperature exposure up to 800 C and freeze/thaw cycles on its value are studied.In order to analyze the observed changes in moisture diffusivity and thermal parameters, thermal analysis and visual analysis are performed. As the main reason for these changes, the crack formation is identified. Particularly, the magnitude of variations of moisture diffusivity is found to be affected by the quality of aggregates rather than by the quality of cement
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JI - Kompositní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GV103%2F97%2FK003" target="_blank" >GV103/97/K003: Materiálové modely betonu pro posouzení nadprojektových havárií jaderných elektráren</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Concrete for Extreme Conditions
ISBN
0 7277 3178 5
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
765-774
Název nakladatele
Thomas Telford Publishing
Místo vydání
London
Místo konání akce
Dundee, Scotland
Datum konání akce
9. 9. 2002
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—