Thermal and Hygric Properties of a Carbon-Fiber Reinforced Cement Composite Material after Thermal Load
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F02%3A01075453" target="_blank" >RIV/68407700:21110/02:01075453 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Thermal and Hygric Properties of a Carbon-Fiber Reinforced Cement Composite Material after Thermal Load
Popis výsledku v původním jazyce
Moisture diffusivity, high temperature thermal diffusivity, room temperature thermal conductivity, specific heat and water vapor permeability of a carbon fiber reinforced cement composite material are measured on specimens thermally loaded by subjectingto a temperature up to 1000 0C prior to the measurement. The linear thermal expansion coefficient is due to the character of the measuring method measured in the high temperature range to 1000 0C without any pre-treatment. The values of moisture diffusivity are found to depend on the thermal load in a very significant way, the maximum increase compared to the unloaded samples being two orders of magnitude. The changes of other studied parameters are lower but also significant. The water vapor permeability increases up to 4.5 times, the room temperature thermal conductivity decreases by 25% and the specific heat decreases by 20%
Název v anglickém jazyce
Thermal and Hygric Properties of a Carbon-Fiber Reinforced Cement Composite Material after Thermal Load
Popis výsledku anglicky
Moisture diffusivity, high temperature thermal diffusivity, room temperature thermal conductivity, specific heat and water vapor permeability of a carbon fiber reinforced cement composite material are measured on specimens thermally loaded by subjectingto a temperature up to 1000 0C prior to the measurement. The linear thermal expansion coefficient is due to the character of the measuring method measured in the high temperature range to 1000 0C without any pre-treatment. The values of moisture diffusivity are found to depend on the thermal load in a very significant way, the maximum increase compared to the unloaded samples being two orders of magnitude. The changes of other studied parameters are lower but also significant. The water vapor permeability increases up to 4.5 times, the room temperature thermal conductivity decreases by 25% and the specific heat decreases by 20%
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JI - Kompositní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Tagungsbeiträge Proceedings
ISBN
3-86005-322-1
ISSN
—
e-ISSN
—
Počet stran výsledku
9
Strana od-do
351-359
Název nakladatele
Technische Universität Dresden
Místo vydání
Dresden
Místo konání akce
Dresden
Datum konání akce
26. 9. 2002
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—