Water and water vapor transport in two-layer systems where one layer acts as water retarder are analyzed. In the experimental work, four external paints supposed to protect the underlying structure against water under common service conditions are applied on glass fiber reinforced concrete substrates. The water absorption coefficient and the effective water vapor diffusion coefficient are chosen as evaluation parameters for the assessment of water and water vapor transport properties of the systems. Inthe water absorption experiments, two consecutive quasi-steady regimes are identified, the first with an almost constant water flux into the system, and the second obeying the square-root-of-time rule for cumulative mass of water in the system. The waterprotective qualities of all studied paints can be considered as satisfactory for common service conditions
Název v anglickém jazyce
Water and Water Vapor Penetration Through Coatings
Popis výsledku anglicky
Water and water vapor transport in two-layer systems where one layer acts as water retarder are analyzed. In the experimental work, four external paints supposed to protect the underlying structure against water under common service conditions are applied on glass fiber reinforced concrete substrates. The water absorption coefficient and the effective water vapor diffusion coefficient are chosen as evaluation parameters for the assessment of water and water vapor transport properties of the systems. Inthe water absorption experiments, two consecutive quasi-steady regimes are identified, the first with an almost constant water flux into the system, and the second obeying the square-root-of-time rule for cumulative mass of water in the system. The waterprotective qualities of all studied paints can be considered as satisfactory for common service conditions
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JJ - Ostatní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Thermal Envelope & Building Science
ISSN
1097-1963
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
13
Strana od-do
165-177
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—