The Effect of Thermal and Mechanical Load on the Moisture Diffusivity of Two Carbon Fiber Reinforced Cement Composites
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F03%3A01088444" target="_blank" >RIV/68407700:21110/03:01088444 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Effect of Thermal and Mechanical Load on the Moisture Diffusivity of Two Carbon Fiber Reinforced Cement Composites
Popis výsledku v původním jazyce
The liquid moisture transport in two different types of carbon fiber reinforced cement composites is studied in dependence on thermal load up to 10000C, tensile stress up to breaking value and their combination. The preheating temperature is identified as the most important factor affecting the moisture diffusivity. The differences between the reference specimens and specimens preheated to 10000C are around two orders of magnitude. The effect of tensile load is found to be negligible compared to the reference values. Also the combined effects of tensile and thermal load do not lead to any significant differences compared to the thermally loaded specimens. The magnitude of changes in moisture diffusivity in dependence on preheating temperature is foundto be also strongly affected by the type of cement used in the particular carbon fiber reinforced cement composites
Název v anglickém jazyce
The Effect of Thermal and Mechanical Load on the Moisture Diffusivity of Two Carbon Fiber Reinforced Cement Composites
Popis výsledku anglicky
The liquid moisture transport in two different types of carbon fiber reinforced cement composites is studied in dependence on thermal load up to 10000C, tensile stress up to breaking value and their combination. The preheating temperature is identified as the most important factor affecting the moisture diffusivity. The differences between the reference specimens and specimens preheated to 10000C are around two orders of magnitude. The effect of tensile load is found to be negligible compared to the reference values. Also the combined effects of tensile and thermal load do not lead to any significant differences compared to the thermally loaded specimens. The magnitude of changes in moisture diffusivity in dependence on preheating temperature is foundto be also strongly affected by the type of cement used in the particular carbon fiber reinforced cement composites
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JI - Kompositní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of International Workshop: Physical and Material Engineering 2003
ISBN
80-227-1924-2
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
91-96
Název nakladatele
STU
Místo vydání
Bratislava
Místo konání akce
Richňava
Datum konání akce
3. 9. 2003
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—