V článku je uvedeno semi-scale testování kritického detailu obvodového pláště s vnitřní tepelnou izolací ve 2-D
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F04%3A01096641" target="_blank" >RIV/68407700:21110/04:01096641 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Application of Microwave Impulse Method for Measuring Moisture Profiles in Building Materials
Popis výsledku v původním jazyce
The moisture profiles were determined using a common capillary suction 1-D experiment in the horizontal position, lateral sides of specimens were water and vapor-proof insulated. Scanning by microwave impulse moisture meter along the specimen was done every 10 mm. The calibration curve was determined after the last scanning, when the moisture penetration front was at about one half of the length of the specimen, using this last scanning and the standard gravimetric method after cutting the specimen into10 mm wide pieces. The calibration curve presents the moisture content in building material in dependence on permittivity of this measured material. The permittivity of measured material was calculated on the basis of measuring the time difference , where t2 is the travel time of the impulse to pass the thickness of measured specimen and t1 the respective travel time in the air. The moisture profiles were then calculated from the calibration curve. The measurements were done at 25 C .
Název v anglickém jazyce
Application of Microwave Impulse Method for Measuring Moisture Profiles in Building Materials
Popis výsledku anglicky
The moisture profiles were determined using a common capillary suction 1-D experiment in the horizontal position, lateral sides of specimens were water and vapor-proof insulated. Scanning by microwave impulse moisture meter along the specimen was done every 10 mm. The calibration curve was determined after the last scanning, when the moisture penetration front was at about one half of the length of the specimen, using this last scanning and the standard gravimetric method after cutting the specimen into10 mm wide pieces. The calibration curve presents the moisture content in building material in dependence on permittivity of this measured material. The permittivity of measured material was calculated on the basis of measuring the time difference , where t2 is the travel time of the impulse to pass the thickness of measured specimen and t1 the respective travel time in the air. The moisture profiles were then calculated from the calibration curve. The measurements were done at 25 C .
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JJ - Ostatní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of Workshop 2004
ISBN
80-01-02945-X
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
560-561
Název nakladatele
ČVUT
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
22. 3. 2004
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—