VLIV REZOLUCE CT DAT A PROSTOROVÉHO PRŮMĚROVÁNÍ NA PROUDĚNÍ VODY V 3D HETEROGENNÍM PÓROVITÉM SYSTÉMU
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F04%3A01104913" target="_blank" >RIV/68407700:21110/04:01104913 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of CT image resolution and spatial averaging on three-dimensional heterogeneous water flow
Popis výsledku v původním jazyce
This contribution aims at evaluating different degree of soil sample heterogeneity with emphasis on resulting water fluxes. Sandy loam soil from Korkusova Hut was subject to CT imaging with high resolution. The three-dimensional distribution of CT-derived porosity within the sample was used in numerical experiments. Voxel porosity was employed for the calculation of the distribution of hydraulic conductivity scaling factor. Water flow through the heterogeneous soil sample was simulated by 3D model basedon Richards' macroscopic concept. From our simulations, it follows that the spatial averaging is less appropriate technique, since it alters significantly the original CT data. Generally, reducing the CT acquired information in model input weakens the impact of heterogeneous structures and thus provides less realistic description of the flow in the soil under the study.
Název v anglickém jazyce
Effect of CT image resolution and spatial averaging on three-dimensional heterogeneous water flow
Popis výsledku anglicky
This contribution aims at evaluating different degree of soil sample heterogeneity with emphasis on resulting water fluxes. Sandy loam soil from Korkusova Hut was subject to CT imaging with high resolution. The three-dimensional distribution of CT-derived porosity within the sample was used in numerical experiments. Voxel porosity was employed for the calculation of the distribution of hydraulic conductivity scaling factor. Water flow through the heterogeneous soil sample was simulated by 3D model basedon Richards' macroscopic concept. From our simulations, it follows that the spatial averaging is less appropriate technique, since it alters significantly the original CT data. Generally, reducing the CT acquired information in model input weakens the impact of heterogeneous structures and thus provides less realistic description of the flow in the soil under the study.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
DF - Pedologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/SA%2F650%2F5%2F03" target="_blank" >SA/650/5/03: Labe IV</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
80-89139-05-1
Místo vydání
Bratislava
Název nakladatele resp. objednatele
—
Verze
—
Identifikační číslo nosiče
neuvedeno