Dřík kyčelního implantátu s gradientem elastických vlastností - jak eliminovat "štítový efekt"u rigidních implantátů?
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F04%3A01105432" target="_blank" >RIV/68407700:21110/04:01105432 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Hip Replacements with the Gradient of Elastic Properties - How to Eliminate a Shield Effect of Rigid Replacements
Popis výsledku v původním jazyce
A human femur is loaded by a wide range of dynamic effects which are transferred by the walls of a cortical bone and has substantial influence on the natural functioning of bone tissue. By the application of rigid or quasi-elastic stems of implants in afemur cavity, the physiological distribution of forces in the wall of the femur diaphysis is impaired, and its flexural rigidity is increased. The increase in flexural rigidity of a cortical bone after the implantation of a rigid replacement leads to thereduction of load in a cortical bone, namely in its proximal part. Our effort is aimed at minimizing a "shield effect" that arises in this way, and at the maximum possible approximation to the natural transition of the stress that is typical of a soundbone.
Název v anglickém jazyce
Hip Replacements with the Gradient of Elastic Properties - How to Eliminate a Shield Effect of Rigid Replacements
Popis výsledku anglicky
A human femur is loaded by a wide range of dynamic effects which are transferred by the walls of a cortical bone and has substantial influence on the natural functioning of bone tissue. By the application of rigid or quasi-elastic stems of implants in afemur cavity, the physiological distribution of forces in the wall of the femur diaphysis is impaired, and its flexural rigidity is increased. The increase in flexural rigidity of a cortical bone after the implantation of a rigid replacement leads to thereduction of load in a cortical bone, namely in its proximal part. Our effort is aimed at minimizing a "shield effect" that arises in this way, and at the maximum possible approximation to the natural transition of the stress that is typical of a soundbone.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA106%2F03%2F0255" target="_blank" >GA106/03/0255: Řízení bioadhese pojivové tkáně k polymerovým kompozitům</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
80-7043-315-9
Místo vydání
Plzeň
Název nakladatele resp. objednatele
—
Verze
—
Identifikační číslo nosiče
neuvedeno