Analýza interakce dodatečných vnějších kontaktních zateplovacích systémů a obvodových plášťů panelových domů ze sendvičových panelů délky 6,0 m
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F04%3A01107613" target="_blank" >RIV/68407700:21110/04:01107613 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Analysis of the Interaction of the Additional Outside Contact Padding Warm Systems with Prefabricated Sandwich Panel Claddings 6,0 m in Lenght
Popis výsledku v původním jazyce
There is the statistically important number of failures of the additional thermal insulating systems of the prefabricated panel buildings claddings in the Czech Republic. A great deal of them was detected aproximatelly 10 - 15 years ago. The additional outside contact padding warm systems (OCPWS) of the prefabricated panel buildings claddings are strained, besides common influences, compared to other types of claddings also by one specific unfavourable effect, which is dilatation movements of background, which is represented by partial panels of cladding. The stress of this structure caused by dilatation movements, which is major in the case that cladding is made of sandwich panel elements, can cause significant decreasing of reliability and life cycleof the OCPWS.
Název v anglickém jazyce
The Analysis of the Interaction of the Additional Outside Contact Padding Warm Systems with Prefabricated Sandwich Panel Claddings 6,0 m in Lenght
Popis výsledku anglicky
There is the statistically important number of failures of the additional thermal insulating systems of the prefabricated panel buildings claddings in the Czech Republic. A great deal of them was detected aproximatelly 10 - 15 years ago. The additional outside contact padding warm systems (OCPWS) of the prefabricated panel buildings claddings are strained, besides common influences, compared to other types of claddings also by one specific unfavourable effect, which is dilatation movements of background, which is represented by partial panels of cladding. The stress of this structure caused by dilatation movements, which is major in the case that cladding is made of sandwich panel elements, can cause significant decreasing of reliability and life cycleof the OCPWS.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Environmental Compatible Structures and Structural Materials
ISBN
80-01-03150-0
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
97-102
Název nakladatele
ČVUT, Fakulta stavební
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
24. 6. 2004
Typ akce podle státní příslušnosti
EUR - Evropská akce