The Hydraulic Capacity of Sewer System Scanned by CCTV Inspection
Popis výsledku v původním jazyce
Sewer and wastewater systems suffer from insufficient capacity, construction flaws and pipe deterioration. Hydraulic simulations are usually done running commercial models that apply, as input, default values of parameters that strongly influence results. Using CCTV inspections data to cataloguefailures affecting pipes, a 3D model was used to evaluate their hydraulic consequences. The translation of failures effects in parameters values producing the same hydraulic conditions caused by failures was donethrough the comparison of laboratory experiences and 3D simulations results. This will move the results from 1D models closer to reality and decrees a number of calibrations needs. It can be also used during the operation time for changing performance capacity due to deduction of failures, or for prediction of capacity due to predicted failures on a sewer system.
Název v anglickém jazyce
The Hydraulic Capacity of Sewer System Scanned by CCTV Inspection
Popis výsledku anglicky
Sewer and wastewater systems suffer from insufficient capacity, construction flaws and pipe deterioration. Hydraulic simulations are usually done running commercial models that apply, as input, default values of parameters that strongly influence results. Using CCTV inspections data to cataloguefailures affecting pipes, a 3D model was used to evaluate their hydraulic consequences. The translation of failures effects in parameters values producing the same hydraulic conditions caused by failures was donethrough the comparison of laboratory experiences and 3D simulations results. This will move the results from 1D models closer to reality and decrees a number of calibrations needs. It can be also used during the operation time for changing performance capacity due to deduction of failures, or for prediction of capacity due to predicted failures on a sewer system.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
DJ - Znečištění a kontrola vody
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP103%2F05%2FP184" target="_blank" >GP103/05/P184: Interakce odlehčovacích komor stokových sítí s recipientem</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
87-89220-80-3
Místo vydání
Lyngby
Název nakladatele resp. objednatele
—
Verze
—
Identifikační číslo nosiče
neuvedeno