Vizualizace proudového pole odlehčovací komory
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F06%3A01122326" target="_blank" >RIV/68407700:21110/06:01122326 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Flow Pattern Visualization of Combined Sewer Overflow
Popis výsledku v původním jazyce
Presented paper deals with 2D flow visualization using Ultrasonic Doppler Method (UDM). The flow patterns in the axes of plane symmetry of designed combined sewer overflow (CSO) were measured on the hydraulic model made of plexiglass using Ultrasonic Velocity Profile (UVP) Monitor. The experiments were focused on both, the optimalization of CSO geometry and the verification of the 3D CFD model. The results show great potential of the UDM in combination with numerical analysis to visualize 2D flow field.Moreover, the optimal geometrical configuration with respect to the gravitational separation of suspended solids content and separation of floatable solids was found as well. The comparison between experimental values and CFD simulations introduces sufficient agreement.
Název v anglickém jazyce
Flow Pattern Visualization of Combined Sewer Overflow
Popis výsledku anglicky
Presented paper deals with 2D flow visualization using Ultrasonic Doppler Method (UDM). The flow patterns in the axes of plane symmetry of designed combined sewer overflow (CSO) were measured on the hydraulic model made of plexiglass using Ultrasonic Velocity Profile (UVP) Monitor. The experiments were focused on both, the optimalization of CSO geometry and the verification of the 3D CFD model. The results show great potential of the UDM in combination with numerical analysis to visualize 2D flow field.Moreover, the optimal geometrical configuration with respect to the gravitational separation of suspended solids content and separation of floatable solids was found as well. The comparison between experimental values and CFD simulations introduces sufficient agreement.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA103%2F04%2F1350" target="_blank" >GA103/04/1350: Interakce městského odvodnění a recipientu při extrémních hydrologických stavech</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 20th Symposium on Anemometry
ISBN
80-239-7144-1
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
121-124
Název nakladatele
Ústav pro hydrodynamiku AVČR
Místo vydání
Praha
Místo konání akce
Holany-Litice
Datum konání akce
6. 6. 2006
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—