Nový způsob stanovení optimálních teplot v interiéru budovy.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F07%3A01143421" target="_blank" >RIV/68407700:21110/07:01143421 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The substitution of comfort PMV values by a new experimental operative temperature
Popis výsledku v původním jazyce
Problems following the application of optimal operative temperatures estimated on the basis of PMV and the necessity to apply correct values into the new Czech Government Directive No. 523/2002 Code led to experiments based on the the physiological humanbody response instead of on solely man's feelings in a defined environment. On the basis of experiments on 32 subjects (university students) it has been possible to estimate: a) total balance of hydrothermal flows between the human body and environment,b) the optimal operative temperature as a function of the subject's aktivity, c) the thermoregulatory range for each optimal operative temperature, i. e. maximal (category Cmax) limited by the beginnings of sweating, minimal (category Cmin)limited by the beginnings of shivering (category C can be applied to the natural ventilated buildings).
Název v anglickém jazyce
The substitution of comfort PMV values by a new experimental operative temperature
Popis výsledku anglicky
Problems following the application of optimal operative temperatures estimated on the basis of PMV and the necessity to apply correct values into the new Czech Government Directive No. 523/2002 Code led to experiments based on the the physiological humanbody response instead of on solely man's feelings in a defined environment. On the basis of experiments on 32 subjects (university students) it has been possible to estimate: a) total balance of hydrothermal flows between the human body and environment,b) the optimal operative temperature as a function of the subject's aktivity, c) the thermoregulatory range for each optimal operative temperature, i. e. maximal (category Cmax) limited by the beginnings of sweating, minimal (category Cmin)limited by the beginnings of shivering (category C can be applied to the natural ventilated buildings).
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
WellBeing Indoors Proceedings CD-ROM
ISBN
978-952-99898-3-6
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
FINVAC
Místo vydání
Helsinki
Místo konání akce
Helsinky
Datum konání akce
10. 6. 2007