Odolnost historické kamené konstrukce Karlova mostu 2: Citlivost na nesilové účinky
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F08%3A01142895" target="_blank" >RIV/68407700:21110/08:01142895 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Failure Resistance of the Historic Stone Bridge Structure of Charles Bridge. I: Susceptibility to Nonstress Effects
Popis výsledku v původním jazyce
The monitoring of deformations of the stone structure of Charles Bridge in Prague proved the gravity and relevance of nonstress effects (temperature, moisture content) on cyclic deformations and permanent strain accompanied by a gradual disintegration ofits stone masonry, growing tilt of the breast walls, and development of cracks in the masonry of the stone bridge structure. Each deformation cycle is accompanied by a gradual growth in permanent deformations. The "unmanifested" primary deformation dueto, e.g., a temperature change causes a mechanical state of tension, and it is mainly the tensile stresses thus arising that contribute to the development of tensile cracks in the stone masonry.
Název v anglickém jazyce
Failure Resistance of the Historic Stone Bridge Structure of Charles Bridge. I: Susceptibility to Nonstress Effects
Popis výsledku anglicky
The monitoring of deformations of the stone structure of Charles Bridge in Prague proved the gravity and relevance of nonstress effects (temperature, moisture content) on cyclic deformations and permanent strain accompanied by a gradual disintegration ofits stone masonry, growing tilt of the breast walls, and development of cracks in the masonry of the stone bridge structure. Each deformation cycle is accompanied by a gradual growth in permanent deformations. The "unmanifested" primary deformation dueto, e.g., a temperature change causes a mechanical state of tension, and it is mainly the tensile stresses thus arising that contribute to the development of tensile cracks in the stone masonry.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Performance of Constructed Facilities
ISSN
0887-3828
e-ISSN
—
Svazek periodika
22
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
12
Strana od-do
—
Kód UT WoS článku
000254426800003
EID výsledku v databázi Scopus
—