Měření průtoku v otevřených korytech: Laboratorní experimenty
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F08%3A01148394" target="_blank" >RIV/68407700:21110/08:01148394 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Open-channel Discharge Measurement based on Ultrasonic Doppler Velocity Profiling - Laboratory Experiments
Popis výsledku v původním jazyce
Presented study deals with the design, the experimental evaluation and the verification of the novel methodology for open-channel discharge measurement suitable especially for the short-term monitoring. The methodology is based on an error-minimized application of ultrasonic velocity profiling method enabling the measurement of instantaneous velocity distribution over the entire flow depth without direct contact with the flowing liquid. The total relative bias of measured and reference values of the discharge from all experiments was 3.2 %. Results show that the relative error increases with the flow depth. The influence of side walls on the velocity distribution in verticals close to the channel walls is clearly stated. The results show high accuracyof presented flow rate measurement methodology and demonstrate its great potential to identify hydraulic singularities in open-channel flows.
Název v anglickém jazyce
Open-channel Discharge Measurement based on Ultrasonic Doppler Velocity Profiling - Laboratory Experiments
Popis výsledku anglicky
Presented study deals with the design, the experimental evaluation and the verification of the novel methodology for open-channel discharge measurement suitable especially for the short-term monitoring. The methodology is based on an error-minimized application of ultrasonic velocity profiling method enabling the measurement of instantaneous velocity distribution over the entire flow depth without direct contact with the flowing liquid. The total relative bias of measured and reference values of the discharge from all experiments was 3.2 %. Results show that the relative error increases with the flow depth. The influence of side walls on the velocity distribution in verticals close to the channel walls is clearly stated. The results show high accuracyof presented flow rate measurement methodology and demonstrate its great potential to identify hydraulic singularities in open-channel flows.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP103%2F07%2FP269" target="_blank" >GP103/07/P269: Dlouhodobý monitoring průtoku kapalin v otevřených korytech pomocí vizuálního sledování pohybu částic</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 6th Int. Symposium on Ultrasonic Doppler Methods for Fluid Mechanics and Fluid Engineering
ISBN
978-80-87117-05-7
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
České vysoké učení technické v Praze
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
9. 9. 2008