Hygrothermal Performance Study of an Innovative Interior Thermal Insulation System
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F09%3A00154615" target="_blank" >RIV/68407700:21110/09:00154615 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Hygrothermal Performance Study of an Innovative Interior Thermal Insulation System
Popis výsledku v původním jazyce
An innovative interior thermal insulation system on the basis of hydrophilic mineral wool which can serve as an alternative solution to the commonly used systems with water vapor barrier is presented in the paper. At first, the process of materials design is described. Then, the hygrothermal performance of the designed insulation system is tested in the difference climate conditions that correspond to the winter climate in Middle Europe. In the experiment, the profiles of temperature, relative humidityand liquid moisture content are monitored. Measured temperature profiles demonstrate the proper thermal insulation function of the system. The hygric function can also be considered very good as no water condensation during the whole testing period of five months appears in the insulation layer.
Název v anglickém jazyce
Hygrothermal Performance Study of an Innovative Interior Thermal Insulation System
Popis výsledku anglicky
An innovative interior thermal insulation system on the basis of hydrophilic mineral wool which can serve as an alternative solution to the commonly used systems with water vapor barrier is presented in the paper. At first, the process of materials design is described. Then, the hygrothermal performance of the designed insulation system is tested in the difference climate conditions that correspond to the winter climate in Middle Europe. In the experiment, the profiles of temperature, relative humidityand liquid moisture content are monitored. Measured temperature profiles demonstrate the proper thermal insulation function of the system. The hygric function can also be considered very good as no water condensation during the whole testing period of five months appears in the insulation layer.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Thermal Engineering
ISSN
1359-4311
e-ISSN
—
Svazek periodika
29
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
—
Kód UT WoS článku
000265465100008
EID výsledku v databázi Scopus
—