Energy efficient buildings; design and energy calculations in variants
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F09%3A00166533" target="_blank" >RIV/68407700:21110/09:00166533 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Energy efficient buildings; design and energy calculations in variants
Popis výsledku v původním jazyce
The paper deals with energy efficient buildings, briefly defines their features, requirements, gives an information of what has the most influence on energy need for heating and presents the main classification of these buildings. The necessity of a different way designing these buildings, so-called integrated design is outlined. The point of design and energy assessment in variants is given too. The second part of the article shows an example of variant calculations of energy need for heating and the summer overheating risk assessment in the initial stage of the sports complex design, when with respect to the documentation stage there was not enough information and therefore all the input data was not known. Furthermore, it allowed for the results toinfluence decisions in subsequent design stages.
Název v anglickém jazyce
Energy efficient buildings; design and energy calculations in variants
Popis výsledku anglicky
The paper deals with energy efficient buildings, briefly defines their features, requirements, gives an information of what has the most influence on energy need for heating and presents the main classification of these buildings. The necessity of a different way designing these buildings, so-called integrated design is outlined. The point of design and energy assessment in variants is given too. The second part of the article shows an example of variant calculations of energy need for heating and the summer overheating risk assessment in the initial stage of the sports complex design, when with respect to the documentation stage there was not enough information and therefore all the input data was not known. Furthermore, it allowed for the results toinfluence decisions in subsequent design stages.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GD103%2F09%2FH095" target="_blank" >GD103/09/H095: Udržitelná výstavba budov a udržitelný rozvoj sídel</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Workshop W1-2009 Proceedings of workshop
ISBN
978-80-01-04463-6
ISSN
—
e-ISSN
—
Počet stran výsledku
12
Strana od-do
—
Název nakladatele
vydavatelství ČVUT v Praze
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
23. 11. 2009
Typ akce podle státní příslušnosti
EUR - Evropská akce