Material Dispersion Influence on Chromatic Sensors Measurement Accuracy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F10%3A00166043" target="_blank" >RIV/68407700:21110/10:00166043 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21220/10:00166043
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Material Dispersion Influence on Chromatic Sensors Measurement Accuracy
Popis výsledku v původním jazyce
The use of non-contact chromatic confocal sensors in industry is nowadays very widespread. These sensors are based on the dependence of longitudinal chromatic aberration of optical systems on wavelength and measurement systems based on this principle give very good and accurate results in the case of pure reflection of the measuring beam from the investigated object (e.g. reflection from metals etc.). In case we need to measure the thickness of transparent materials (e.g. plan-parallel glass plates) andsimultaneously we want to measure the topography of tested object surfaces then chromatic sensor based measurement systems produce errors due to the dispersion of transparent media (e.g. glass) of measured objects. The work deals with a physical originof these errors and analysis of the influence of these errors on the accuracy of measurement using chromatic sensors. Relations for quantitative evaluation of these errors are derived.
Název v anglickém jazyce
Material Dispersion Influence on Chromatic Sensors Measurement Accuracy
Popis výsledku anglicky
The use of non-contact chromatic confocal sensors in industry is nowadays very widespread. These sensors are based on the dependence of longitudinal chromatic aberration of optical systems on wavelength and measurement systems based on this principle give very good and accurate results in the case of pure reflection of the measuring beam from the investigated object (e.g. reflection from metals etc.). In case we need to measure the thickness of transparent materials (e.g. plan-parallel glass plates) andsimultaneously we want to measure the topography of tested object surfaces then chromatic sensor based measurement systems produce errors due to the dispersion of transparent media (e.g. glass) of measured objects. The work deals with a physical originof these errors and analysis of the influence of these errors on the accuracy of measurement using chromatic sensors. Relations for quantitative evaluation of these errors are derived.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Workshop 2010
ISBN
978-80-01-04513-8
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
—
Název nakladatele
České vysoké učení technické v Praze
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
22. 2. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—