Terrestrial Laser Scanning for the Fire Test on Experimental Building in Mokrsko
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F10%3A00168292" target="_blank" >RIV/68407700:21110/10:00168292 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Terrestrial Laser Scanning for the Fire Test on Experimental Building in Mokrsko
Popis výsledku v původním jazyce
A fire test on experimental object v Mokrsko took place in autumn 2008. The main goal of the fire test was to verify total behaviour of the construction exposed to fire, which cannot be observed only on the separate elements. Geodetic measurements were carried out within this test. Laser scanning method was used in two of three stages of geodetic works. In the first stage it was scanning of the whole interior of the object 14 days before fire. The second stage was measurement of the construction after the fire test. There were observed and evaluated individual construction elements of the object, cellular beams and beams with corrugated webs, columns and different types of wall constructions. Values of vertical and horizontal shifts for beams were found out. Difference models of wall constructions characterizing their deformation after the fire test were created. The gained results serve for analysis of behaviour of experimental construction simulating administration building.
Název v anglickém jazyce
Terrestrial Laser Scanning for the Fire Test on Experimental Building in Mokrsko
Popis výsledku anglicky
A fire test on experimental object v Mokrsko took place in autumn 2008. The main goal of the fire test was to verify total behaviour of the construction exposed to fire, which cannot be observed only on the separate elements. Geodetic measurements were carried out within this test. Laser scanning method was used in two of three stages of geodetic works. In the first stage it was scanning of the whole interior of the object 14 days before fire. The second stage was measurement of the construction after the fire test. There were observed and evaluated individual construction elements of the object, cellular beams and beams with corrugated webs, columns and different types of wall constructions. Values of vertical and horizontal shifts for beams were found out. Difference models of wall constructions characterizing their deformation after the fire test were created. The gained results serve for analysis of behaviour of experimental construction simulating administration building.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
DE - Zemský magnetismus, geodesie, geografie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
The XXIV FIG International Congress 2010 Proceedings
ISBN
978-87-90907-87-7
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
—
Název nakladatele
FIG
Místo vydání
Copenhagen
Místo konání akce
Sydney
Datum konání akce
11. 4. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—