Static design of thermal insulating steel connections
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F10%3A00169291" target="_blank" >RIV/68407700:21110/10:00169291 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Static design of thermal insulating steel connections
Popis výsledku v původním jazyce
According to the increasing requirements of energy efficiency of buildings the new type of thermal insulating joint has been developed. The bolted end-plate connection of steel structures with the intermediate insulating layer will break the thermal bridges in the external cladding. The insulating layer made of technical plastics in the connection has not only the insulating function but also the bearing function to transfer the internal forces appearing in the joint. The design of the thermal insulating joint is using the component method as the design of common steel joints, with a simple modification for the new component "insulating layer in compression". The experiments have been done with the new component as well as with the whole joint and haveshown a good agreement with the calculated values. The new solution for the thermal insulating joint is statically functional, easy to design, energy saving and economically efficient.
Název v anglickém jazyce
Static design of thermal insulating steel connections
Popis výsledku anglicky
According to the increasing requirements of energy efficiency of buildings the new type of thermal insulating joint has been developed. The bolted end-plate connection of steel structures with the intermediate insulating layer will break the thermal bridges in the external cladding. The insulating layer made of technical plastics in the connection has not only the insulating function but also the bearing function to transfer the internal forces appearing in the joint. The design of the thermal insulating joint is using the component method as the design of common steel joints, with a simple modification for the new component "insulating layer in compression". The experiments have been done with the new component as well as with the whole joint and haveshown a good agreement with the calculated values. The new solution for the thermal insulating joint is statically functional, easy to design, energy saving and economically efficient.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/OC09065" target="_blank" >OC09065: Metoda komponent pro spoje bez tepelných mostů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Central Europe towards Sustainable Building
ISBN
978-80-247-3624-2
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Czech Technical University
Místo vydání
Prague
Místo konání akce
Praha
Datum konání akce
30. 6. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—