Thermal and hygric properties of autoclaved aerated concrete
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F10%3A00171331" target="_blank" >RIV/68407700:21110/10:00171331 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Thermal and hygric properties of autoclaved aerated concrete
Popis výsledku v původním jazyce
Thermal and hygric transport and storage properties of two different autoclaved aerated concretes (AAC) are studied and compared with the data published by the particular producers. Apparent moisture diffusivity is determined using the results of water sorptivity measurements, water vapor diffusion permeability is measured by the cup method. Sorption isotherms are determined by the desiccator method in the range of relative humidity of 11% - 96%. Thermal conductivity and specific heat capacity are measured by impulse technique. The obtained data will serve as input parameters for service life prediction models of AAC-based structures. Using this kind of precise data already in the design process can help in reduction of failures of AAC building envelopes.
Název v anglickém jazyce
Thermal and hygric properties of autoclaved aerated concrete
Popis výsledku anglicky
Thermal and hygric transport and storage properties of two different autoclaved aerated concretes (AAC) are studied and compared with the data published by the particular producers. Apparent moisture diffusivity is determined using the results of water sorptivity measurements, water vapor diffusion permeability is measured by the cup method. Sorption isotherms are determined by the desiccator method in the range of relative humidity of 11% - 96%. Thermal conductivity and specific heat capacity are measured by impulse technique. The obtained data will serve as input parameters for service life prediction models of AAC-based structures. Using this kind of precise data already in the design process can help in reduction of failures of AAC building envelopes.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA103%2F09%2F0016" target="_blank" >GA103/09/0016: Vlhkostní, tepelná a mechanická analýza inovovaných obvodových plášťů na bázi pórobetonu zaměřená na problémy trvanlivosti</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Thermophysics 2010
ISBN
978-80-214-4166-8
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
—
Název nakladatele
VUT v Brně
Místo vydání
Brno
Místo konání akce
Valtice
Datum konání akce
3. 11. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—