A round-robin test of Czech airtightness test providers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F10%3A00174930" target="_blank" >RIV/68407700:21110/10:00174930 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A round-robin test of Czech airtightness test providers
Popis výsledku v původním jazyce
The round-robin test of Czech airtightness providers was organised in order to obtain information about the measurement equipment generally used and in order to compare the test results given by different technicians operating with different devices. Allthe participants measured the same building under very similar conditions. All the test results were evaluated according to EN 13829. 23 technicians participated with 14 measuring devices of 4 different types. In total, 16 particular tests were performed. The test results and ongoing simple analyses indicate that the participants provide comparable test results expressed in terms of n50 and V50 values. The test results seem to be independent of the type of measuring device. However, a systematically different course of the air leakage function was observed in case of one type of measuring device. Furthermore, it seems that the experience and skills of a technician might have a certain influence on the test result.
Název v anglickém jazyce
A round-robin test of Czech airtightness test providers
Popis výsledku anglicky
The round-robin test of Czech airtightness providers was organised in order to obtain information about the measurement equipment generally used and in order to compare the test results given by different technicians operating with different devices. Allthe participants measured the same building under very similar conditions. All the test results were evaluated according to EN 13829. 23 technicians participated with 14 measuring devices of 4 different types. In total, 16 particular tests were performed. The test results and ongoing simple analyses indicate that the participants provide comparable test results expressed in terms of n50 and V50 values. The test results seem to be independent of the type of measuring device. However, a systematically different course of the air leakage function was observed in case of one type of measuring device. Furthermore, it seems that the experience and skills of a technician might have a certain influence on the test result.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1M0579" target="_blank" >1M0579: Centrum integrovaného navrhování progresivních stavebních konstrukcí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů