Development of sustainable material effective structure is based on the effort to reduce primary non-renewable material consumption. Utilization of high performance concrete creates the conditions for the dimension optimization, leading to the savings inraw materials and thus to the more favourable environmental characteristics of implemented structures. The aim of the research was to verify the potential design of slender waffle floor structures with minimized thickness of upper slab (25 to 30 mm). Overall properties of 12 different fibre concrete mixtures were tested in order to find out optimal material for the waffle floor structure. The materials were validated both from the mechanical and environmental perspective. The final test specimens in the form of representative segment of waffle floor slab were tested by the combination of torsion and bending. The environmental evaluation of samples proved that by the shape and material optimization up to 70% of material can be saved.
Název v anglickém jazyce
Utilization of high performance silicate composites in material effective building structures
Popis výsledku anglicky
Development of sustainable material effective structure is based on the effort to reduce primary non-renewable material consumption. Utilization of high performance concrete creates the conditions for the dimension optimization, leading to the savings inraw materials and thus to the more favourable environmental characteristics of implemented structures. The aim of the research was to verify the potential design of slender waffle floor structures with minimized thickness of upper slab (25 to 30 mm). Overall properties of 12 different fibre concrete mixtures were tested in order to find out optimal material for the waffle floor structure. The materials were validated both from the mechanical and environmental perspective. The final test specimens in the form of representative segment of waffle floor slab were tested by the combination of torsion and bending. The environmental evaluation of samples proved that by the shape and material optimization up to 70% of material can be saved.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Central Europe towards Sustainable Building
ISBN
978-80-247-3624-2
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
411-414
Název nakladatele
Czech Technical University
Místo vydání
Prague
Místo konání akce
Praha
Datum konání akce
30. 6. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000288408300094