Hygric and Thermal Properties of Materials Involved in the Envelopes of Contemporary Buildings
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F11%3A00181231" target="_blank" >RIV/68407700:21110/11:00181231 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Hygric and Thermal Properties of Materials Involved in the Envelopes of Contemporary Buildings
Popis výsledku v původním jazyce
The hygric and thermal properties of building materials are an indispensable part of the input parameters database of HEMOT computer code for modeling coupled heat and moisture transport in building envelope systems. In this paper, the methods for determination of hygric and thermal properties of materials which are used in contemporary buildings in Czech Republic are demonstrated on the example of expanded polystyrene. Apparent moisture diffusivity is determined by method utilizing the results of watersorptivity measurements, water vapor diffusion permeability is measured by the cup method. Sorption isotherms are determined by the desiccator method in the range of relative humidity of 11%-96%. Thermal conductivity and specific heat capacity are measured by an impulse technique. Finally, an example of calculation of temperature and moisture fields in two typical building envelopes using the HEMOT computer code is given.
Název v anglickém jazyce
Hygric and Thermal Properties of Materials Involved in the Envelopes of Contemporary Buildings
Popis výsledku anglicky
The hygric and thermal properties of building materials are an indispensable part of the input parameters database of HEMOT computer code for modeling coupled heat and moisture transport in building envelope systems. In this paper, the methods for determination of hygric and thermal properties of materials which are used in contemporary buildings in Czech Republic are demonstrated on the example of expanded polystyrene. Apparent moisture diffusivity is determined by method utilizing the results of watersorptivity measurements, water vapor diffusion permeability is measured by the cup method. Sorption isotherms are determined by the desiccator method in the range of relative humidity of 11%-96%. Thermal conductivity and specific heat capacity are measured by an impulse technique. Finally, an example of calculation of temperature and moisture fields in two typical building envelopes using the HEMOT computer code is given.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ME10112" target="_blank" >ME10112: Řízený návrh tepelně izolačního systému moderních budov na základě tepelně vlhkostní analýzy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Modern Methods and Advances in Structural Engineering and Construction
ISBN
978-981-08-7920-4
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
807-812
Název nakladatele
Research Publishing Services
Místo vydání
Singapore
Místo konání akce
Zurich
Datum konání akce
21. 6. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—