Simulation of the Mechanical Behaviour of a Single Human Trabecula assessed with a Micromechanical Test and Nanoindentation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F11%3A00182836" target="_blank" >RIV/68407700:21110/11:00182836 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68378297:_____/11:00364803 RIV/68407700:21260/11:00182836
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Simulation of the Mechanical Behaviour of a Single Human Trabecula assessed with a Micromechanical Test and Nanoindentation
Popis výsledku v původním jazyce
The paper presents a comparison between mechanical properties of single human trabeculae obtained by micromechanical testing and those assessed by nanoindentation. Compact uniaxial tension/compression device has been developed for this purpose. The strains at the surface of the sample are measured optically using a high-resolution CCD camera. The strain field is evaluated using image correlation technique. Local micromechanical properties were assessed using nanoindentation. From obtained nanoindentation curves material parameters for elasto-plastic constitutive model with isotropic hardening are identified in a FE simulation of the indentation process. The unknown parameters are identified in a large set of parametric studies in which the response ofthe model is best-fitted to the experimental curve. Validation of the material model obtained from nanoindentation is presented in simulation of the tensile test of single trabecula.
Název v anglickém jazyce
Simulation of the Mechanical Behaviour of a Single Human Trabecula assessed with a Micromechanical Test and Nanoindentation
Popis výsledku anglicky
The paper presents a comparison between mechanical properties of single human trabeculae obtained by micromechanical testing and those assessed by nanoindentation. Compact uniaxial tension/compression device has been developed for this purpose. The strains at the surface of the sample are measured optically using a high-resolution CCD camera. The strain field is evaluated using image correlation technique. Local micromechanical properties were assessed using nanoindentation. From obtained nanoindentation curves material parameters for elasto-plastic constitutive model with isotropic hardening are identified in a FE simulation of the indentation process. The unknown parameters are identified in a large set of parametric studies in which the response ofthe model is best-fitted to the experimental curve. Validation of the material model obtained from nanoindentation is presented in simulation of the tensile test of single trabecula.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FI - Traumatologie a ortopedie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the Thirteenth International Conference on Civil, Structural and Environmental Engineering Computiing
ISBN
978-1-905088-46-1
ISSN
1759-3433
e-ISSN
—
Počet stran výsledku
12
Strana od-do
1-12
Název nakladatele
Civil-Comp Press
Místo vydání
Edinburgh
Místo konání akce
Chania
Datum konání akce
6. 9. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—