There is a need to reduce people´s fear of fires to increase the use of wood as a structural material. The correct modelling of the fire and sufficient knowledge of wood behaviour at elevated temperatures leads to the improvement and specification of theresults of the fire resistance times. The assessment of wooden structures in terms of fire resistance can be mode using national technical standards and manuals, the calculation according to Eurocode (EN 1995-1-2) or fire tests. The computational procedures given by Eurocode 5 are applicable to elements of wood and wood-based materials, selected connections and exactly specified panels and this for the maximum fire resistance of 60 min. It can be verified for wall (floor) assemblies in addition to solving the load-bearing function (criterion R) and the separating function (criterions E, I). This paper is focused on timber structures exposed to fire, especially on the contribution to the fire resistance of timber structures boards.
Název v anglickém jazyce
COMPUTATIONAL MODELS FOR DETERMINING THE CONTRIBUTION TO THE FIRE RESISTANCE OF TIMBER STRUCTURES
Popis výsledku anglicky
There is a need to reduce people´s fear of fires to increase the use of wood as a structural material. The correct modelling of the fire and sufficient knowledge of wood behaviour at elevated temperatures leads to the improvement and specification of theresults of the fire resistance times. The assessment of wooden structures in terms of fire resistance can be mode using national technical standards and manuals, the calculation according to Eurocode (EN 1995-1-2) or fire tests. The computational procedures given by Eurocode 5 are applicable to elements of wood and wood-based materials, selected connections and exactly specified panels and this for the maximum fire resistance of 60 min. It can be verified for wall (floor) assemblies in addition to solving the load-bearing function (criterion R) and the separating function (criterions E, I). This paper is focused on timber structures exposed to fire, especially on the contribution to the fire resistance of timber structures boards.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JM - Inženýrské stavitelství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Wood and fire safety 2012
ISBN
978-80-87427-23-1
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
119-126
Název nakladatele
University of Žilina
Místo vydání
Žilina
Místo konání akce
Štrbské Pleso
Datum konání akce
13. 5. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—