Evaluation of sewer infiltration/inflow using COD mass flux method: case study Prague
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F12%3A00195878" target="_blank" >RIV/68407700:21110/12:00195878 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of sewer infiltration/inflow using COD mass flux method: case study Prague
Popis výsledku v původním jazyce
The combined sewer system of the City of Prague, similar to other relevant locations, is strongly affected by infiltrating waters. The knowledge of their volume is one of the important parameter with respect to sewer system operation, maintenance and reconstruction. The methodology is based on the variation of diurnal COD load and continuous water quality monitoring using in-line absorption spectrometry. This approach allows the identification of individual components of the diurnal waste water hydrograph, in particular the contribution of parasitic water flow on waste water discharge. The statistical relevance was tested using Monte Carlo simulations on a seven-year data series of flow rate. The results show that application of this methodology provides specific relevant information about individual subcatchments within an entire sewer system, particulary in terms of absolute and relative values of I/I and structural state indicators. Processing of long-term data series gives clear in
Název v anglickém jazyce
Evaluation of sewer infiltration/inflow using COD mass flux method: case study Prague
Popis výsledku anglicky
The combined sewer system of the City of Prague, similar to other relevant locations, is strongly affected by infiltrating waters. The knowledge of their volume is one of the important parameter with respect to sewer system operation, maintenance and reconstruction. The methodology is based on the variation of diurnal COD load and continuous water quality monitoring using in-line absorption spectrometry. This approach allows the identification of individual components of the diurnal waste water hydrograph, in particular the contribution of parasitic water flow on waste water discharge. The statistical relevance was tested using Monte Carlo simulations on a seven-year data series of flow rate. The results show that application of this methodology provides specific relevant information about individual subcatchments within an entire sewer system, particulary in terms of absolute and relative values of I/I and structural state indicators. Processing of long-term data series gives clear in
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DJ - Znečištění a kontrola vody
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA103%2F08%2F0134" target="_blank" >GA103/08/0134: Rizika hydraulického selhání stokové sítě</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Water Science & Technology
ISSN
0273-1223
e-ISSN
—
Svazek periodika
66
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
673-680
Kód UT WoS článku
000306240200028
EID výsledku v databázi Scopus
—