Technical Note: Evaluation of between-sample memory effects in the analysis of 2H and 18O of water samples measured by laser spectroscopes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F12%3A00196762" target="_blank" >RIV/68407700:21110/12:00196762 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00025798:_____/12:00000349
Výsledek na webu
<a href="http://www.hydrol-earth-syst-sci.net/16/3925/2012/hess-16-3925-2012.html" target="_blank" >http://www.hydrol-earth-syst-sci.net/16/3925/2012/hess-16-3925-2012.html</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5194/hess-16-3925-2012" target="_blank" >10.5194/hess-16-3925-2012</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Technical Note: Evaluation of between-sample memory effects in the analysis of 2H and 18O of water samples measured by laser spectroscopes
Popis výsledku v původním jazyce
This study evaluated between-sample memory in isotopic measurements of 2H and 18O in water samples by laser spectroscopy. Ten isotopically depleted water samples spanning a broad range of oxygen and hydrogen isotopic compositions were measured by three generations of offaxis integrated cavity output spectroscopy and cavity ringdown spectroscopy instruments. The analysis procedure encompassed small (less than 2permille for 2H and 1permille for 18O) and large (up to 201permille for 2H and 25permille for 18O) differences in isotopic compositions between adjacent sample vials. Samples were injected 18 times each, and the betweensample memory effect was quantified for each analysis run. Results showed that samples adversely affected by betweensample isotopic differences stabilised after seven-eight injections. The between-sample memory effect ranged from 14% and 9% for 2H and 18O measurements, respectively, but declined to negligible carryover (between 0.1% and 0.3% for both isotopes) when
Název v anglickém jazyce
Technical Note: Evaluation of between-sample memory effects in the analysis of 2H and 18O of water samples measured by laser spectroscopes
Popis výsledku anglicky
This study evaluated between-sample memory in isotopic measurements of 2H and 18O in water samples by laser spectroscopy. Ten isotopically depleted water samples spanning a broad range of oxygen and hydrogen isotopic compositions were measured by three generations of offaxis integrated cavity output spectroscopy and cavity ringdown spectroscopy instruments. The analysis procedure encompassed small (less than 2permille for 2H and 1permille for 18O) and large (up to 201permille for 2H and 25permille for 18O) differences in isotopic compositions between adjacent sample vials. Samples were injected 18 times each, and the betweensample memory effect was quantified for each analysis run. Results showed that samples adversely affected by betweensample isotopic differences stabilised after seven-eight injections. The between-sample memory effect ranged from 14% and 9% for 2H and 18O measurements, respectively, but declined to negligible carryover (between 0.1% and 0.3% for both isotopes) when
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DA - Hydrologie a limnologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Hydrology and Earth System Sciences
ISSN
1027-5606
e-ISSN
—
Svazek periodika
16
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
9
Strana od-do
3925-3933
Kód UT WoS článku
000310474300029
EID výsledku v databázi Scopus
—