Evaluation of Cable Forces in the Roof Structure at RCP Amazon Court
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F12%3A00199378" target="_blank" >RIV/68407700:21110/12:00199378 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of Cable Forces in the Roof Structure at RCP Amazon Court
Popis výsledku v původním jazyce
The paper presents the results of an experiment carried out on the cables of the roof structure of the RCP Amazon Court. The tensile forces in the roof cables were determined using vibration frequency method (VFM). The VFM is often used in practice because it provides an efficient, cheap and relatively easy way to determine the cable forces and a standard measuring line for dynamic experiments can be used. The paper also discusses the task of the result accuracy of the used methods. The results of the described experiment show that production tolerances and mounting method can significantly influence the stresses in statically indeterminate load bearing structure with cables. Therefore, it is important to verify forces in cables experimentally in thesestructures during their construction and it is also suitable to monitor cable forces during their service life.
Název v anglickém jazyce
Evaluation of Cable Forces in the Roof Structure at RCP Amazon Court
Popis výsledku anglicky
The paper presents the results of an experiment carried out on the cables of the roof structure of the RCP Amazon Court. The tensile forces in the roof cables were determined using vibration frequency method (VFM). The VFM is often used in practice because it provides an efficient, cheap and relatively easy way to determine the cable forces and a standard measuring line for dynamic experiments can be used. The paper also discusses the task of the result accuracy of the used methods. The results of the described experiment show that production tolerances and mounting method can significantly influence the stresses in statically indeterminate load bearing structure with cables. Therefore, it is important to verify forces in cables experimentally in thesestructures during their construction and it is also suitable to monitor cable forces during their service life.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JM - Inženýrské stavitelství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Recent Advances in Mechanical Engineering and Automatic Control
ISBN
978-1-61804-142-5
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
98-103
Název nakladatele
WSEAS Press
Místo vydání
Athens
Místo konání akce
Paris
Datum konání akce
2. 12. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce