Experiments on membrane action of composite floors with steel fibre reinforced concrete slab exposed to fire
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F13%3A00205360" target="_blank" >RIV/68407700:21110/13:00205360 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.elsevier.com/locate/firesaf" target="_blank" >http://www.elsevier.com/locate/firesaf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.bbr.2011.03.031" target="_blank" >10.1016/j.bbr.2011.03.031</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experiments on membrane action of composite floors with steel fibre reinforced concrete slab exposed to fire
Popis výsledku v původním jazyce
The resistance of composite floor structures traditionally composes of the elemental resistance of the concrete slab and that of the composite beams. The fire resistance of a properly designed floor structure increases due to its membrane behaviour. Itsevaluation is based on advanced as well as simple design procedures approved by tests, for partially protected floors reaching 60 min and more. Composite structures are increasingly reinforced by steel fibres instead of steel bars. Due to an equal distribution of reinforcement steel fibre reinforced concrete (SFRC) achieves better deformation capacity compared to the traditional reinforced concrete even at elevated temperatures. Therefore, questions have been raised about its fire resistance and utilisation of membrane action of the floor.
Název v anglickém jazyce
Experiments on membrane action of composite floors with steel fibre reinforced concrete slab exposed to fire
Popis výsledku anglicky
The resistance of composite floor structures traditionally composes of the elemental resistance of the concrete slab and that of the composite beams. The fire resistance of a properly designed floor structure increases due to its membrane behaviour. Itsevaluation is based on advanced as well as simple design procedures approved by tests, for partially protected floors reaching 60 min and more. Composite structures are increasingly reinforced by steel fibres instead of steel bars. Due to an equal distribution of reinforcement steel fibre reinforced concrete (SFRC) achieves better deformation capacity compared to the traditional reinforced concrete even at elevated temperatures. Therefore, questions have been raised about its fire resistance and utilisation of membrane action of the floor.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JM - Inženýrské stavitelství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP105%2F10%2F2159" target="_blank" >GAP105/10/2159: Modely membránového působení stropních desek vystavených požáru</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Fire Safety Journal
ISSN
0379-7112
e-ISSN
—
Svazek periodika
59
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
11
Strana od-do
111-121
Kód UT WoS článku
000321178900013