Indoor Environmental Quality in Naturally Ventilated Office Building
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F13%3A00205758" target="_blank" >RIV/68407700:21110/13:00205758 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21720/13:00205758
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Indoor Environmental Quality in Naturally Ventilated Office Building
Popis výsledku v původním jazyce
The paper deals with an indoor environment quality evaluation of old naturally ventilated office building in Prague, Czech Republic. Background research describes indoor climate components and their influence on occupants, describes indoor climate evaluation methods and summarizes required indoor climate parameter value limits. Field work was focused on a measurement of indoor environment parameters in one office buildings. Measured values were evaluated and PMV and PPD indices were calculated. Indicesvalues were used for evaluating indoor environment according to the standard ČSN EN ISO 7730. Next part of research included an indoor environment quality questionnaire taken from occupant subjective perspective. The office evaluation was done accordingto a thermal comfort of the body as whole and local thermal discomfort. Local thermal comfort parameters were calculated from values which were found in Design Builder software model. There is a comparison of results gained through measur
Název v anglickém jazyce
Indoor Environmental Quality in Naturally Ventilated Office Building
Popis výsledku anglicky
The paper deals with an indoor environment quality evaluation of old naturally ventilated office building in Prague, Czech Republic. Background research describes indoor climate components and their influence on occupants, describes indoor climate evaluation methods and summarizes required indoor climate parameter value limits. Field work was focused on a measurement of indoor environment parameters in one office buildings. Measured values were evaluated and PMV and PPD indices were calculated. Indicesvalues were used for evaluating indoor environment according to the standard ČSN EN ISO 7730. Next part of research included an indoor environment quality questionnaire taken from occupant subjective perspective. The office evaluation was done accordingto a thermal comfort of the body as whole and local thermal discomfort. Local thermal comfort parameters were calculated from values which were found in Design Builder software model. There is a comparison of results gained through measur
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Clima 2013 - 11th REHVA World Congress & 8th International Conference on IAQVEC - "Energy Efficient, Smart and Healthy Buildings"
ISBN
978-80-260-4001-9
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
3713-3722
Název nakladatele
Společnost pro techniku prostředí
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
16. 6. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—