Use of Composite Timber-concrete Structure while Ttimber Floor Reconstruction in Existing Buildings
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F13%3A00206624" target="_blank" >RIV/68407700:21110/13:00206624 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Use of Composite Timber-concrete Structure while Ttimber Floor Reconstruction in Existing Buildings
Popis výsledku v původním jazyce
The paper is focused on the issue of timber ceiling reconstruction in existing buildings. The condition of timber beams as a part of the structure is mostly insufficient based just on a visual assessment of mechanical properties of the structural members. It is necessary to determine the strength and modulus of elasticity of timber as accurately as possible in order to preserve this kind of structures. Many non-destructive methods are available to use, especially those operating with ultrasound waves and stress waves because they are absolutely non-invasive. Velocity of wave propagation depends on both quality of timber (its density) and presence of defects (knots, cracks). It is also possible to use less invasive methods, e.g. resistance drilling or pushing of a pin into wood. In a case that higher resistance and stiffness of the ceiling are needed, it could be reinforced by slim concrete desk that is coupled with timber beams by various connectors. Also the impact sound insulation an
Název v anglickém jazyce
Use of Composite Timber-concrete Structure while Ttimber Floor Reconstruction in Existing Buildings
Popis výsledku anglicky
The paper is focused on the issue of timber ceiling reconstruction in existing buildings. The condition of timber beams as a part of the structure is mostly insufficient based just on a visual assessment of mechanical properties of the structural members. It is necessary to determine the strength and modulus of elasticity of timber as accurately as possible in order to preserve this kind of structures. Many non-destructive methods are available to use, especially those operating with ultrasound waves and stress waves because they are absolutely non-invasive. Velocity of wave propagation depends on both quality of timber (its density) and presence of defects (knots, cracks). It is also possible to use less invasive methods, e.g. resistance drilling or pushing of a pin into wood. In a case that higher resistance and stiffness of the ceiling are needed, it could be reinforced by slim concrete desk that is coupled with timber beams by various connectors. Also the impact sound insulation an
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
CESB 13 Central Europe towards Sustainable Building 2013
ISBN
978-80-247-5018-7
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
67-70
Název nakladatele
GRADA PUBLISHING
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
26. 6. 2013
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—