Timber-concrete composite structures are becoming very important because they are widely used as an effective method for refurbishment of existing timber floors and for floors of new multi-storey timber houses. The reinforcement of the concrete slab is necessary, but leads to a large slab thickness. Therefore it is reasonable to replace the usual reinforced concrete by steel fibre reinforced concrete. One of the most important requirements of these structures is fire resistance. This paper presents theexperimental work of testing timber-fibre concrete composite floors at ambient and elevated temperature. Furnace test was performed on one full-size floor specimen at the Fire testing laboratory PAVUS. It was subjected the standard fire for over 150 min.The membrane effect of the floor was progressively activated. Material properties tests were made at ambient and elevated temperature. There were detected tensile strength and ductility of fibre reinforced concrete.
Název v anglickém jazyce
TIMBER-FIBRE CONCRETE COMPOSITE FLOOR IN FIRE
Popis výsledku anglicky
Timber-concrete composite structures are becoming very important because they are widely used as an effective method for refurbishment of existing timber floors and for floors of new multi-storey timber houses. The reinforcement of the concrete slab is necessary, but leads to a large slab thickness. Therefore it is reasonable to replace the usual reinforced concrete by steel fibre reinforced concrete. One of the most important requirements of these structures is fire resistance. This paper presents theexperimental work of testing timber-fibre concrete composite floors at ambient and elevated temperature. Furnace test was performed on one full-size floor specimen at the Fire testing laboratory PAVUS. It was subjected the standard fire for over 150 min.The membrane effect of the floor was progressively activated. Material properties tests were made at ambient and elevated temperature. There were detected tensile strength and ductility of fibre reinforced concrete.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JM - Inženýrské stavitelství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP105%2F10%2F2159" target="_blank" >GAP105/10/2159: Modely membránového působení stropních desek vystavených požáru</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník semináře doktorandů katedry ocelových a dřevěných konstrukcí
ISBN
978-80-01-05289-1
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
47-52
Název nakladatele
ČVUT, Fakulta stavební, Katedra ocelových a dřevěných konstrukcí
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
26. 3. 2013
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—